Mantracourt Electronics Limited

 SerialDis User Manual     

 

Multidrop RS232 

 

TX

SW1 set for baudrate of 19200 and an address of 1 (left) and 2 (right)

GND

R S232 Serial Device

GND
+V

ON

OFF

 

 
 
 
 
Multidrop RS485 

 

GND

B

Switch position 1 must be on to terminate RS485 bus. (Last device on bus)

SW1 set for baudrate of 38400 and an address of 8 (left) and 9 (right)

A

R S485 Serial Device

+V

GND
+V

ON

OFF

 

Summary of Contents for SERIALDIS

Page 1: ...SERIALDIS Serial ASCII Display Module User Manual MICRON METERS metersinfo micronmeters com www micronmeters com ...

Page 2: ... 2 Requirements 2 Configuration 2 Operation 2 Physical Connections 2 Single PC Connection 2 Multidrop RS232 3 Multidrop RS485 3 Configuration 4 Error Reporting 4 Control Codes 4 Addressing 5 Display Examples 5 Character Representations 6 Specification 7 Environmental 7 CE Approvals 7 Warranty 7 ...

Page 3: ...y a carriage return The baudrate is selectable from 9600 to 115200 but is fixed at 8 data bits 1 stop bit and no parity Configuration Configuration is by DIP switches where the baudrate and address can be set Operation The display accepts ASCII data and on receipt of a carriage return character decimal 13 hexadecimal 0D the data will be displayed Physical Connections Single PC Connection View from...

Page 4: ...baudrate of 19200 and an address of 1 left and 2 right GND RS232 Serial Device GND V ON OFF Multidrop RS485 GND B Switch position 1 must be on to terminate RS485 bus Last device on bus SW1 set for baudrate of 38400 and an address of 8 left and 9 right A RS485 Serial Device V GND V ON OFF ...

Page 5: ...0 Off On 19200 On Off 38400 On On 115200 Address Set the address of the display To disable addressing set to all Off 5 6 7 8 Off Off Off Off 0 Off Off Off On 1 Off Off On Off 2 Off Off On On 3 Off On Off Off 4 Off On Off On 5 Off On On Off 6 Off On On On 7 On Off Off Off 8 On Off Off On 9 On Off On Off 10 On Off On On 11 On On Off Off 12 On On Off On 13 On On On Off 14 On On On On 15 NOTE DIP swit...

Page 6: ...dress a particular module send the special control character 0x01 followed by a byte indicating the address i e To send data to display module addressed as 7 the following would be sent 0x01 0x07 123 456 0x0D Where the square brackets indicate a single byte whose value is shown in hexadecimal If data is sent with no addressing control bytes then all displays will show the data If a module is addre...

Page 7: ...ntracourt Electronics Limited SerialDis User Manual 6 Character Representations 0 1 2 3 4 5 6 7 8 9 a b c d e f g h i j k l m n o p q r s t u v w x y z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z ...

Page 8: ...me company address phone number and a detailed description of the problem Also please indicate if it is a warranty repair The sender is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit Mantracourt warranty does not apply to defects resulting from action of the buyer such as mishandling improper interfacing operation outside of design limits imp...

Reviews: