20.03.2009
6
Assembly
1.
Screw the applicator unit support stand (A) together with
the stand foot (B).
2.
Screw the spray hood together with the height
adjustment (B) and the unit support beam (C).
3.
Connect the electrical plug connectors (D) together.
4.
Screw the flow rate control (E) onto the unit support
beam (C).
5.
Screw the handle bar (G) together with the handle bar
extension (F)
6.
Insert the handle bar extension (F) into the unit support
beam (C) and tighten securely.
7.
Slide the powerpack (H) into the designated bracket on
the unit support beam (C) and tighten securely.
8.
Insert the phone jack (I) into the plug socket on the
powerpack (H).
9.
Attach the hose (J) onto the lower side of the flow rate
control (E).
Metering table
Roundup UltraMax application rate 2 l/ha at 20 °C
Spray width
in cm
Metering
adjustment
knob position
Required output volume
in ml per atomiser
with 50 wheel revolutions
60
70
80
90
100
110
A
B
C
D
E
F
approx. 3.8
approx. 4.4
approx. 5.0
approx. 5.6
approx. 6.3
approx. 6.9
Calculating divergent application rates:
Factor x
Spray width in cm
=
Required volume per atomiser
in ml with 50 wheel revolutions
Factor for 1 l/ha: 0,031
Factor for 2 l/ha: 0,063
Factor for 3 l/ha: 0,094
Adjusting the spray width
a)
Loosen the spray hood screws in the elongated holes
on the upper side of the sheet metal skirt and unscrew
the screws from the front side of the sheet metal skirt.
b)
Adjust the segmental rotation atomiser to the desired
width (see page 3 of the Operating Instructions).
c)
Retighten the screws.
Checking the output volume
1.
Place an underlay (e.g. cardboard or paper) on the
ground and prop up the unit on stands.
2.
Fill the chemical tank with herbicide - undiluted.
3.
Remove the hose from the lower side of the flow rate
control and place a measuring cup underneath.
4.
Open the shut-off valve, initially setting the metering
adjustment knob to the maximum flow rate and
simultaneously turning the wheel; wait until the
chemical solution is evenly applied.
5.
Set the chemical solution volume according to the
output table.
6.
Volume calibration: Collect the chemical solution from
50 wheel revolutions into a measuring cup. If the
desired volume is not reached, set a larger or a
smaller volume with the pump metering adjustment
knob.
7.
Perform volume calibration again.
8.
Reconnect the hose on the lower side of the flow rate
control.
9.
The unit is now ready for deployment.
Maximum allowable wheel pressure 3.5 bar
Shut-off valve position closed
MANKAR-P 60-80
MANKAR-P 70-110
Spray hood 60-80