4. Parameter set up
Press +key, go into set model, user can set up shortage voltage, light
wheels, speed signal.
a. Shortage of voltage set up: while the display indicate set , VOL and PO
figure , set up shortage of voltage , throughout quick press key to up or
down value .
b. Wheel diameter set up : when quick press under display indicates set
and p 1 . quick press key to up or down value .
c. Signal of monitor speed set up . short press , under display indicates p3 ,
quick press key set up 1 or 0 ( 0 means none implement this function )
d. Motor pole reduce ratio set up : short press key , indicates set , p 2 and,
use the hall signal to replace of speed signal.
e. Long press key , to quit set up model and save all changed data.
5. Failing model indicator
When the vehicle with abnormal status ,the instrument may show some
parts ,like stopper breakdown ,motor breakdown or handle bar
breakdown and controller breakdown