For the correct functioning of the pump use exclusively chemical products of BP descaling line. 

It 

is suggested for a long duration of the device to not leave any acid products inside the tank, once 
the cleaning process is over, and to let circulate for few minutes  the neutralizing solution Neutral 
Liquid or Neutral Powder, in order to eliminate acid debris present inside the system.

WHAT DO I NEED TO INSTALL IT

• 

Flexible pipes for an easier connection

• 

Nipples

• 

Connections

• 

Typical plumber ‘tool for connections of different type.

CORRECT INSTALLATION

1.

 Control, as first thing (if it is possible) 

if inside the device that has to be des-
caled, there is enough space to guaran-
tee the passage for the acid solution on 
the contrary, the operation is not possible.

2.

  Disconnect the outlet and inlet of the de-

vice to descale, if it is possible, drain it from 
the internal water and then connect it to the 
pump, through the use of equipped pipes.

3.

 Remove the tank cap and add cold wa-

ter up to half tank (please notice that 
operational temperature during des-
caling must never exceed 60 °C).

4.

  Turn the pump on with the switch and start 

adding slowly the descaling chemical, un-
til required concentration is obtained.

This operation guarantees the correct acid 
product blending. Please carefully follow use 
and safety information reported on the la-
bel of product. Anyway, maximum operation-
al time (continuously) of the motor, should 
not exceed 2 hours. Please after 2 hours, 
let  the  system  rest  for  at  least  half  an  hour.             
ATTENTION: on all version equipped with 
Flow Inverter (FI) the acid solution flow can 
be inverted  acting on the external control 

APPLICATION AND USE

Descaling pump for boil-
ers, heat exchangers, 
plastic press moulding 
machines, wall-mounted 
and floor standing boil-
ers. Boss 36 and Boss 
36 FI, have as accessory 
a gasket and a screwing 
cap ACID TANK 36 code 
300610008 where the ready-to-use acid solution, could be prepared. This guarantees to have al-
ways available the pump for the neutralizing solution, so maximum safety and protection of the 
pump and of the system that has to be descaled. Thanks to the possibility of unscrewing and screw-
ing the pump in 10” and without any tools, Manta is the only manufacturing company, that guaran-
tees  to be in the working place with both acid solution and neutralizing solution ready for the rapid use.

INSTALLAZIONE

 

CORRETTA

Reviews: