Manta AVS 4401765 Installation Manual Download Page 6

             

AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5 

 

Boot release output (150mA max): 

Press  the 

  button  for  three  seconds.  The  system  will  disarm,  the  doors  will  unlock  (if  central  locking 

connected) and the boot output wire will give a negative output for one second. For safety reasons the boot release 

will  not  work  with  the  ignition on. The boot release can also be programmed to operate instantly when the 

 

button is pushed (refer Register 1, Feature 6). 

 

The  boot release button is also used to control the on-board turbo timer function (refer Turbo timer set-up). If the 
on-board turbo timer feature is used, remote boot release is not available. 
 
Auto zone bypass: 
Auto bypass is designed to reduce false alarms caused by faulty switches or external sensors. If the alarm is triggered 
three  times  by  the same sector then that sector will be bypassed. (i.e.  the sector will become inactive.) The sector 
will  only  be  bypassed  for  one  arming period. The next time the system is armed the sector that was bypassed will 
become active again. 
 
Door/bonnet/boot/AUX inputs: 
The door, bonnet, boot and AUX input wires  detect a change of state rather than just a negative input. This means 
for example, if you arm the alarm with the door open the alarm will trigger if the door closes. 
 
Turbo timer functions: 
The system has two turbo timer functions: 

 

On-board turbo timer: allows the vehicle to run for 1, 2 or 4 minutes after the ignition is switched to off. 

 

Interface: will interface with an external turbo timer to allow the vehicle to run on the turbo timer after the 
alarm is armed. 

 

Refer to Turbo Timer Instructions for full details. 
 
Operate system from car’s factory remote (MAP function): 
The system will arm when the factory remote is locked and disarm when unlocked. It requires the factory upgrade 
wires to be connected. 

 

Refer to the Factory Remote Interface (MAP function) section for full details. 
 
Anti hijack: 
There are two anti hijack modes to stop thieves that have possesion of the car key and alarm remote from stealing 
the  vehicle.  A  momentary switch (AVS DS01 is recomended) needs to be pressed within a minute of an anti hijack 
activation or the alarm will cut fuel to the vehicle and sound the alarm (if programmed). 

 

Refer to Anti Hijack Modes for full details. 
 
Courier feature:  
The  alarm  can  be  armed  with  the  ignition  on.  The  alarm allows the vehicle to run indefinitely with the ignition on 
after the alarm is armed. If the alarm is triggered it will shut down the engine and sound the alarm. 

 

Refer to Courier Mode for full details. 
 
Automatic re-arm and re-lock 
This feature prevents the accidental disarming of  the system. It will re-arm and (if central locking is connected) re-
lock  the  doors  if  the  system  is  disarmed  from  an  armed  state  and  a  door  is  not  opened  within  60  seconds.  This 
feature is off by default but it is recommended that it be programmed on (refer Register 2, Feature 4). 

Summary of Contents for AVS 4401765

Page 1: ...XF2106 R2 This product complies with AS NZS 3749 1 2003 Class A Volumetric Sensing glass break shock must be enabled to comply with a Class A installation refer Programmable Features Class A VSAS Veh...

Page 2: ...ons Operate system from car s factory remote Anti hijack modes Courier feature Automatic re arm and re lock 4 5 Additional features Data battery back up siren V2 Intelligent glass break sensor AVS A5...

Page 3: ...1 continued Turbo timer run time On board turbo timer Delayed panic MAP Feature 2 second entry delay Factory remote interface for old OEM Enhancement module Courier mode 15 16 Programming features Re...

Page 4: ...on all inputs and outputs except the immobiliser circuits If the poly fuse detects an overload it will open to prevent damage to the alarm components Once the overload has been removed the polyfuse w...

Page 5: ...d four times upon disarming Low remote battery warning When the battery in the remote is almost flat the remotes LED will flash instead of lighting constantly when a button is pressed Panic car finder...

Page 6: ...timer allows the vehicle to run for 1 2 or 4 minutes after the ignition is switched to off Interface will interface with an external turbo timer to allow the vehicle to run on the turbo timer after th...

Page 7: ...re is disconnected If the alarm is armed or auto immobilised the siren WILL sound if the battery or digital data wire is disconnected Original DBBSM sirens can be used on V5 alarm modules but will beh...

Page 8: ...vailable sequence above 2 A new remote can be coded into the system 12 times You can do this by coding the same remote in even if you only have one remote 3 Or the unit can be sent back to Manta Elect...

Page 9: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 9 NOTE Unless a remote control is learnt in you will need to repeat the procedure every time you wish to start the car...

Page 10: ...ate it is possible to trace the required wires by first un clipping the case Next slide the circuit board out to expose the main connector plug Use the following connector diagram below to trace each...

Page 11: ...her alarm wires marked with red and white sheathing Green this wire gives a constant 200mA negative output alarm when the alarm is triggered It can be used to run additional piezo sirens or to activat...

Page 12: ...gives a 1 second negative output for boot release 150ma maximum For use where electric boot release is to be connected Extra components may be required depending on the vehicle Refer to Remote Boot R...

Page 13: ...allation standards make sure the cut is made more than 300mm from the starter or fuel pump immobiliser cuts IM3A 2 wires and IM3B 2 wires Fuel pump immobiliser circuit The fuel pump wire usually runs...

Page 14: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 14...

Page 15: ...1 Vehicle set up Close all doors bonnet boot arm disarm alarm then turn ignition on off on Feature Arm and disarm chirp Press the button this many times 2 Factory setting ON Description One chirp on a...

Page 16: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 16...

Page 17: ...on This mode allows the installer to verify that each trigger of the alarm system is working without having to arm and disarm the system each time and setting off the siren After pressing the button 1...

Page 18: ...ne thermo fans cut in automatically or there are other accessories active even when the ignition is turned off e g car phones TO ACTIVATE VOLTAGE DROP TURN FEATURE OFF Feature Turbo timer run time Pre...

Page 19: ...onds after pressing the button If the alarm is activated the system will shut the engine down and trigger as normal When in courier mode the glass sensor AVS A5 will be disabled while the engine is ru...

Page 20: ...turned ON the unlock output becomes a 15 second negative pulse instead of 0 5 seconds This feature is for use with vehicles with vacuum central locking Feature Anti Hijack Mode 1 Press the button this...

Page 21: ...larm will also activate for five minutes after the anti hijack trigger can be turned off via Register 2 Feature 11 Feature Alarm on Anti Hijack trigger Press the button this many times 11 Factory sett...

Page 22: ...t ensure the cooling fans continue to run when the vehicle is running on the turbo timer you may need to hook up the second ignition wire relay as per next page Note IM2A MUST BE CONNECTED TO 12V MAIN...

Page 23: ...STALLATION MANUAL GEN 2 VER 5 23 6 Once the desired time duration is selected simply turn the ignition on then off The siren should chirp the new run time setting indicating the turbo timer time durat...

Page 24: ...l arm the alarm and lock the doors as normal but the immobiliser relays will stay closed until the pre programmed time out If the alarm detects an intrusion the alarm will sound and the system will im...

Page 25: ...ement the maximum run time allowed for the turbo timer There are four levels each level is indicated by the number of chirps See table below It is very important that the external turbo timer does not...

Page 26: ...switch to disarm the alarm Inhibit mode is a much more secure upgrade option The table below describes each upgrade wires operation Wire Inhibit mode Enable mode POS1 Positive arm arms the alarm when...

Page 27: ...gnition on then off and the momentary switch is pressed or pin code is entered Mode 1 In mode 1 the unit will enter anti hijack countdown following the opening of a door when the ignition is on Upon e...

Page 28: ...er as normal When in courier mode the glass sensor AVS A5 will be disabled however AUX input remains active when the engine is running but will arm normally when the ignition is off Note The ignition...

Page 29: ...ehicle Connect to lock wire of vehicle 2 Positive pulse CDL system Cut Cut Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Earth Earth Connect to unlock wire of vehicle Connect to lock wire of...

Page 30: ...stem Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Vehicle s Existing CDL Switch Vehicle s Existing Door Motor Cut Cut Earth Connect to relay side of control wire Connect to Unlock COM 5 Sin...

Page 31: ...4 The RCX 4 can also receive these signals and will put out a basic low current negative Note If you want to use the alarm boot pop or alarm panic channel be aware that Ch 2 on the RXPRO or RCX 4 wil...

Page 32: ...yfuse may have tripped Check circuit for excessive current draw or short Polyfuse may take several minutes before resetting Wait and re test Turbo timer problems No engine shut down on boot button Eng...

Reviews: