Manson Engineering Industrial ZVS-8350 User Manual Download Page 2

 

INSTALLATION 

 

1.  This power supply is designed for indoor use only, put the unit in a well  ventilated place and allow at least 50mm  (2 in.) 

space on two sides and the back to allow sufficient fan cooling. 

 

2.  Check for the correct input AC voltage with the rating label on the power supply 

   

  Make sure your mains plug is of 3 pin version and the ground pin is effective as the grounding of the power supply will 

prevent electrical shock caused by leakage. 

 

3.  Turn on the power supply for a few minutes, the power switch (1) should be lit and the indicator (2) should be in green. 

 

4.  Turn off the power supply and connect the equipment with correct polarity. 

 

5.  Turn on the power supply first, then turn on the equipment. 

 

6.  When the operation is finished, turn off the equipment first, then turn off the power supply.   

 

REMOTE CONTROL 

 

ENABLE AND DISABLE THE OUTPUT 

You can use Port 7 and 8 to remote control the OUTPUT ON/OFF. 

a) Open Port 7 and 8 if you want to ENABLE the output (By default) 

b) Short Port 7 and 8 if you want to DISABLE the output. 

 

Set up the provided remote connector plug 

 

(a) 

Remove the black portion of the remote control connector plug by removing the screw as Fig 1. 

 

 

 

     

      

 

(b) 

Solder 2 wires(22AWG) to PORT 7 & 8 of black portion as shown in Fig.2. 

 

 

(c)

 

Make sure the load is disconnected and the power supply is OFF. 

(d)

  Plug the remote connector plug into the remote control terminal of the power supply. 

(e)

  Secure the remote connector plug to the terminal socket by locking connector ring(Fig 3). 

 

 

 

 

 

 

 

 

 

 

Black portion 

Silver portion 

Fig. 1 

Outer ring 

Fig. 3 

Fig. 2 

Port numbers are marked on the black 

portion 

2. Rotate the black portion 

1. Remove the screw 

Reviews: