Manson Engineering Industrial CBC-9140 Operation Manual Download Page 9

Equalization Charge: 

It is only applicable to Lead Acid based battery especially wet type. 
It reconditions the deeply discharged battery and reduces stratification, counter 
sulfation found in deeply discharged and infrequent used battery. It also gives 
battery cells a well balanced charge.

 

Once set, the charging algorithm is automatic. The charger will go through Soft 
Bulk (for deeply discharged battery) -> Bulk -> Absorption -> 

Equalization

 -> 

Float charge stages. 

 

You can exit from Equalization charge to Float anytime by long press at the 
SET button.

 

 

Sleep Mode & Half Power Mode 

Both charge mode have only 20Amp maximum charging current in stead of 
40Amp. 
The cooling fan will be off all the time to ensure total silence of a quiet charging 
operation. 
Half Power mode is more suitable for batteries with less than 135Ah capacity. 
The sleep Mode has an 8 hour timer, charger will go back to normal maximum 
output of 40Amp 
 
Battery with Loads connected such as in caravan, campers & etc. 
The charger can be used as a stand alone automotive charger or connected to 
battery all the time with and without load as long as the load is not more than 
30Amp in normal mode or 15Amp in half power /sleep mode. 
 
 
Lead Acid based batteries: LEAD / AGM   
 

 
 
 
 

P.7 

Summary of Contents for CBC-9140

Page 1: ...al contains important safety and operation instructions for correct use of the battery charger Read through the manual and pay special attention to the markings and labels of the charger battery and e...

Page 2: ...tion Procedure 4 Low Night EQ Selection Procedure 4 Equalization Mode Recondition Mode 4 Recommended Battery Capacity 5 Battery Charger installation and Connection 5 9 Cable size recommendation for 40...

Page 3: ...AGM or LiFePo4 Long Press 5 sec for LOW NIGHT EXIT LOW NIGHT EXIT LOW NIGHT EXIT When battery type set at LEAD Long Press 5 sec for LOW NIGHT EQ EXIT LOW NIGHT EQ EXIT 5 LOW Low Power Mode LED flicke...

Page 4: ...ive out explosive gas Do not charge batteries in an enclosure box in due to possible explosion of entrapped explosive gas Use of accessory not recommended may cause risk of fire electric shock Disconn...

Page 5: ...ry It has temperature compensated charging when connected the supplied battery temperature sensor The Sleep Mode is to ensure a full silent 8 hour charging without cooling fan Control Indicators 1 Bul...

Page 6: ...s The Night Mode has an 8 hour timer and will automatically reset back to normal mode with maximum 40Amp charging current Low mode is more adaptive for battery with less than 135Ah and further extend...

Page 7: ...il the flashing EQ LED goes off follow by Float LED On Recommended Battery Capacity Charging Mode Battery Capacity 40A NORMAL 135Ah to 400Ah 20A LOW or NIGHT MODE 70Ah to 200Ah Battery Charger install...

Page 8: ...attery increases as well Absorption Charge This will give the remaining 20 charge to the battery When the battery voltage rises to the voltage level of the selected battery type the charging switches...

Page 9: ...long press at the SET button Sleep Mode Half Power Mode Both charge mode have only 20Amp maximum charging current in stead of 40Amp The cooling fan will be off all the time to ensure total silence of...

Page 10: ...ent for Lithium FePO4 LFP batteries to ensure safe and optimal charging adaptive to the special chemistry of the battery which is quite different to Lead Acid battery There are only two active chargin...

Page 11: ...r the charging status and do all sorts of setting on the charger without getting to the charger which is most likely installed at hard to access spot This optional Remote Control Module comes with a 1...

Page 12: ...10A 5A Efficiency 91 91 Protections Short Circuit protections self recoverable Over temperature protection 3 steps decrease of output power self recoverable Battery over temperature protection with b...

Page 13: ...Consecutive Rotations Charger over temperature 1 Check cooling fan is working 2 Disconnect any load to battery 3 Disconnect AC source 4 Let charger cool down 5 Double check on correct size of battery...

Page 14: ...his software Manson undertakes no responsibility or liability of losses and damages This apps support Manson CBC 9xxx series with WiFi version Please go to App Store or Google Play to search Magnett C...

Page 15: ...Mounting Hold Diagram P 13...

Reviews: