LEVELING THE WALK-IN TUB
BEFORE Installing the Walk-in Bathtub
1.
Check the floor area where the tub is to be installed.
(a)
Clean area of any debris or trash.
(b)
Use a 5’ or 6’ level and determine if the floor is level. If the floor is not level, adjust all
levelling feet to perfectly level the tub. Note: It is important that all levelling feet are
completely touching the floor and level. You may find you have to adjust the middle legs
lower then the others to slightly raise up the middle of the bath for the door system to
work properly.
2.
Check to ensure that the drain rough has been placed at the proper location.
3.
Ensure that the proper electrical service has been installed at the pump location. See
electrical requirements below.
ELECTRICAL REQUIREMENTS
ELECTRICAL REQUIREMENTS
Equipment utilized on these baths requires individual dedicated electrical service.
Air Bath (8490 and 8590) – One dedicated 120 volt, 15 amp GFCI protected circuit.
Whirlpool (8090 and 8190) - Two separate dedicated 120 volt, 20 amp GFCI protected circuits (15 amp for
Canada).
Combination (8690 and 8790) - Two separate dedicated 120 volt, 20 amp GFCI protected circuits (15 amp for
Canada.
MicroDerm (8890 and 8990) - One dedicated 120 volt, 15 amp GFCI protected circuit.
Service must be a dedicated 15 amp, 120 volt service that is GFCI protected.
ELECTRICAL INSTALLATION
All electrical connections must be carried out by a certified electrician in accordance with local electrical
requirements and codes.
REQUIRED ELECTRICAL RECEPTACLES FOR CANADA