2

 

READ INSTRUCTIONS IN CONJUNCTION WITH 
THE ILLUSTRATIONS 

SAFETY AND GUIDANCE NOTES 

 
 

A.

 

 All wiring to be in accordance with the current I.E.E. Regulations, or the 
appropriate standards of your country and 

MUST 

be installed by a 

suitably qualified person. 

B.

 

 The fan should be provided with a local isolator switch capable of 
disconnecting all poles, having a contact separation of at least 3mm. 

C.

 

 Ensure that the mains supply (Voltage, Frequency, and Phase) complies 
with the rating label. 

D.

 

 It is recommended that the connection to the fan connector terminals is 
made with flexible cable. 

E.

 

 When the fan is used to remove air from a room containing a fuel-
burning appliance, ensure that the air replacement is adequate for both the 
fan and the fuel-burning appliance. 

F.

 

 The fan should not be used where it is liable to be subject to direct water 
spray for prolonged periods of time. 

G.

 

Where ducted fans are used to handle moisture-laden air, a condensation 

trap should be fitted. Horizontal ducts should be arranged to slope slightly 
downwards away from the fan. 

H.

 

This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. 

I.

 

Children should be supervised to ensure that they do not play with the 
appliance. 

J.

 

The 

exterior 

grille should be at least 2.3m above the ground to prevent 

people from being able to access moving parts.  If the 

external

 grille is 

positioned between 0-2.3m from the ground.Please use the an appropriate 
wall kit to ensure people cannot access the fans impeller from the outside. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SLIM F100

Page 1: ...0 16 IP44 F100TS 1 2 3 220 240 50 16 IP44 F100HS 1 2 3 220 240 50 16 IP44 F150 1 2 3 220 240 50 16 IPX4 F150S 1 2 3 220 240 50 16 IPX4 F150T 1 2 3 220 240 50 16 IPX4 F150TS 1 2 3 220 240 50 16 IPX4 F150HS 1 2 3 220 240 50 16 IPX4 H models Humidity Adjustment I To activate the timer function remove jumper JP1 If fitted Once removed the fan will run on for a fixed period of approx 15 mins T models T...

Page 2: ...F The fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time G Where ducted fans are used to handle moisture laden air a condensation trap should be fitted Horizontal ducts should be arranged to slope slightly downwards away from the fan H This appliance is not intended for use by persons including children with reduced physical sensory or menta...

Page 3: ...nd cement both ends into position flush with the wall faces 2 Loosen the screw in the bottom of the grille and remove the front grille Mark the screw centres through the holes in the fan back plate Drill plug and screw into position Fix exterior grille into position with the louvres positioned downwards Note The grille must comply with the standard requirements of your country to prevent access to...

Page 4: ... the fan a fixed over run time of approx 15 mins HUMIDITY SET POINT ADJUSTMENT BEFORE ADJUSTING THE CONTROLLER SWITCH OFF THE MAINS SUPPLY HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grille The controller is factory set to switch on at about 70 RH The humidity set point can be adjusted from 65 95 RH by altering the adjuster on the control PCB 2 To LOWER the se...