READ INSTRUCTIONS IN CONJUNCTION WITH
THE ILLUSTRATIONS
SAFETY AND GUIDANCE NOTES
A.
All wiring to be in accordance with the current I.E.E. Regulations, or the
appropriate standards of your country and
MUST
be installed by a
suitably qualified person.
B.
The fan should be provided with a local isolator switch capable of
disconnecting all poles, having a contact separation of at least 3mm.
C.
Ensure that the mains supply (Voltage, Frequency, and Phase) complies
with the rating label.
D.
It is recommended that the connection to the fan connector terminals is
made with flexible cable.
E.
When the fan is used to remove air from a room containing a fuel-
burning appliance, ensure that the air replacement is adequate for both the
fan and the fuel-burning appliance.
F.
The fan should not be used where it is liable to be subject to direct water
spray for prolonged periods of time.
G.
Where ducted fans are used to handle moisture-laden air, a condensation
trap should be fitted. Horizontal ducts should be arranged to slope slightly
downwards away from the fan.
H.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety.
I.
Children should be supervised to ensure that they do not play with the
appliance.
J.
The
exterior
grille should be at least 2.3m above the ground to prevent
people from being able to access moving parts. If the
external
grille is
positioned between 0-2.3m from the ground.Please use the an appropriate
wall kit to ensure people cannot access the fans impeller from the outside.