WIRING

 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST 
BE ISOLATED FROM THE POWER SUPPLY DURING THE 
INSTALLATION / OR MAINTENANCE

 

IMPORTANT 

  The fan should only be used in conjunction with fixed wiring.  

  The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm

2

  Cable entry can be made from the rear or the side of the fan using the grommet provided. 

  The extraction fan is suitable for connection to 220-240V ~ 50Hz supply.  

  The fan is a class ll double insulated product and 

MUST NOT 

be earthed. 

 

 

1.  Select and follow the appropriate wiring diagram. (Fig. 1, 2 or 3) 
2.  Check all connections have been made correctly and ensure all terminal connections are securely 

fastened. 

3.  Ensure the impeller rotates and is free from obstructions. 

 
SETUP 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE 
ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR 
MAINTENANCE. 
 

See Fig 1, 2, 3, 4, 5, 6 & 7 

 

QF100SX5OP

 – Single speed fan.  Controlled by remote switch (e.g light switch or auto sensor) Fig.1. 

 

QF100TX5OP

 – Single speed fan with overrun Timer* - The fan can be wired to a lighting circuit switch. 

Fig.3. or wired for a basic on/off operation wire as Fig 2. 
When switched ‘ON’, the fan will operate at full speed and will continue to run for a pre-set time after the 
switch is turned ‘OFF’ Overrun timer adjustable 5-30min. See Fig.6. 
 

QF100HTX5OP

 - 

Single speed fan with Humidity Timer* - The fan contains an integral humidity sensor. 

In automatic mode the fan switches on when the room Relative Humidity (RH) increases. The fan will 
continue to run until the room RH falls. These fans also include a built in overrun timer function that is 
adjustable between 5-30 min. See Fig.7. 
 

QF100PIRX5OP

 - PIR* - Single speed with PIR (passive infra-red) detector and overrun timer. The fan 

starts automatically when a movement is detected and will continue to operate for the set overrun time 
period. Fig. 1. 
The fan can also be wired to a lighting circuit switch. Fig.3. so it can be started by the light switch or the PIR 
detector. For timer adjustment see Fig.5. 
 

*All timer versions require a third switch live wire for the timer to work. 
 
 
 
 
 
 

Summary of Contents for Quiet Fan Series

Page 1: ...et Fan X5 T QF100HTX5OP Manrose Quiet Fan X5 HT QF100PIRX5OP Manrose Quiet Fan X5 PIR PLEASE READ THESE INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation and Wiring Instructions Quiet Fan Range 220 240V 50Hz IPX5 ...

Page 2: ...ly Voltage Frequency and Phase complies with the rating label E The Fan should only be used in conjunction with the appropriate Manrose products F The Fan should only be used in conjunction with fixed wiring G When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for both the fan and the fuel burning appliance H The Fan shoul...

Page 3: ...of the fan and pull the grille away from the chassis 4 Mark the screw centres through the holes in the fan back plate Drill plug and screw into position 5 After installation ensure impeller rotates freely and the shutters can open 6 Replace the grille and ensure the clips reactivate WALL MOUNTING 1 For wall mounting either cut a 115mm diameter hole for 100mm fans through the wall and insert the wa...

Page 4: ...mote switch e g light switch or auto sensor Fig 1 QF100TX5OP Single speed fan with overrun Timer The fan can be wired to a lighting circuit switch Fig 3 or wired for a basic on off operation wire as Fig 2 When switched ON the fan will operate at full speed and will continue to run for a pre set time after the switch is turned OFF Overrun timer adjustable 5 30min See Fig 6 QF100HTX5OP Single speed ...

Page 5: ...allation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings which do not require lubrication Fig 1 QF100SX5OP QF100PIRX5OP Fig 2 QF100TX5OP QF100HTX5OP Timer Humidistat disabled 220 240V 50Hz 3 AMP MAX 220 240V 50Hz 3 AMP MAX ...

Page 6: ... use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE 220 240V 50Hz N L LS 3 AMP MAX Timer Adjustment Timer Adjustment To REDUCE the operating time use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE 1 1 ...

Page 7: ...the operating time use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE Humidity Adjustment To INCREASE SET POINT turn the adjuster CLOCKWISE This makes the controller LESS sensitive To REDUCE SET POINT turn the adjuster ANTI CLOCKWISE This makes the controller MORE sensitive Humidity Adjustment Timer Adju...

Page 8: ...Reading RG6 1AZ EU Authorised Representative Manrose Bedrijvenweg 17 7442 CX Nijverdal Nederland authorisedrep manrose nl 496934 A 0621 Contact Information Website www manrose co uk email sales manrose com Sales hotline 01753 691399 Technical hotline 01753 876941 ...

Reviews: