QF100SX5OP 

Manrose Quiet Fan X5 S 

QF100TX5OP 

Manrose Quiet Fan X5 T 

QF100HTX5OP 

Manrose Quiet Fan X5 HT 

QF100PIRX5OP   

Manrose Quiet Fan X5 PIR 

 

 

PLEASE READ THESE INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. 

PLEASE SAVE THESE INSTRUCTIONS. 

 
 
 
 
 
 

 
 
 

 

 

 

 

Installation and Wiring Instructions 

 

 

 

Quiet Fan Range 

220-240V~50Hz 

 

IPX5 

Summary of Contents for Quiet Fan Series

Page 1: ...et Fan X5 T QF100HTX5OP Manrose Quiet Fan X5 HT QF100PIRX5OP Manrose Quiet Fan X5 PIR PLEASE READ THESE INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation and Wiring Instructions Quiet Fan Range 220 240V 50Hz IPX5 ...

Page 2: ...ly Voltage Frequency and Phase complies with the rating label E The Fan should only be used in conjunction with the appropriate Manrose products F The Fan should only be used in conjunction with fixed wiring G When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for both the fan and the fuel burning appliance H The Fan shoul...

Page 3: ...of the fan and pull the grille away from the chassis 4 Mark the screw centres through the holes in the fan back plate Drill plug and screw into position 5 After installation ensure impeller rotates freely and the shutters can open 6 Replace the grille and ensure the clips reactivate WALL MOUNTING 1 For wall mounting either cut a 115mm diameter hole for 100mm fans through the wall and insert the wa...

Page 4: ...mote switch e g light switch or auto sensor Fig 1 QF100TX5OP Single speed fan with overrun Timer The fan can be wired to a lighting circuit switch Fig 3 or wired for a basic on off operation wire as Fig 2 When switched ON the fan will operate at full speed and will continue to run for a pre set time after the switch is turned OFF Overrun timer adjustable 5 30min See Fig 6 QF100HTX5OP Single speed ...

Page 5: ...allation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings which do not require lubrication Fig 1 QF100SX5OP QF100PIRX5OP Fig 2 QF100TX5OP QF100HTX5OP Timer Humidistat disabled 220 240V 50Hz 3 AMP MAX 220 240V 50Hz 3 AMP MAX ...

Page 6: ... use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE 220 240V 50Hz N L LS 3 AMP MAX Timer Adjustment Timer Adjustment To REDUCE the operating time use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE 1 1 ...

Page 7: ...the operating time use a small screwdriver to turn the adjuster ANTI CLOCKWISE To INCREASE the operating time use a small screwdriver to turn the adjuster CLOCKWISE Humidity Adjustment To INCREASE SET POINT turn the adjuster CLOCKWISE This makes the controller LESS sensitive To REDUCE SET POINT turn the adjuster ANTI CLOCKWISE This makes the controller MORE sensitive Humidity Adjustment Timer Adju...

Page 8: ...Reading RG6 1AZ EU Authorised Representative Manrose Bedrijvenweg 17 7442 CX Nijverdal Nederland authorisedrep manrose nl 496934 A 0621 Contact Information Website www manrose co uk email sales manrose com Sales hotline 01753 691399 Technical hotline 01753 876941 ...