Manrose MRHT3 Installation Instructions Manual Download Page 9

10

System Time-Date Settings

S

ystem Time-Date Settings must be entered before Scheduler start times for HEAT TRANSFER can be set.

-  On the Home Screen, press SETTINGS   for 3 seconds to enter Time-Date Settings and follow the guide  

 

  below to complete 

 

NOTE:

 Settings shown are examples only

- Press 

HOME   at any stage to exit and enter Scheduler Settings

- Press 

SETTINGS   at any stage to return to the previous screen

Select

MONTH

value

Go to

DAY DATE

value

Select

DAY DATE

value

Save all

TIME-DATE

settings

Go to

SCHEDULER

settings

Select

DAY

value

Go to
YEAR
value

Confirm

DAY

value

Select

HOUR

value

Go to

MINUTE

value

Confirm

HOUR

value

Confirm
MONTH

value

Select

MINUTE

value

Go to

DAY

value

Confirm
MINUTE

value

Select

YEAR
value

Go to

MONTH

value

Confirm

YEAR
value

Summary of Contents for MRHT3

Page 1: ...3 Room Kit Installation Instructions Firmware Version 2 0...

Page 2: ...rs 6 Fans 7 Inlet Grilles 7 Touch Screen Controller 8 Home Screen Icons 9 Button Functions 9 Screen Highlights 9 System Time Date Settings 10 Commissioning and Testing Inspection Checklist 11 Advanced...

Page 3: ...cleaning recalibration or maintenance All electrical electronic and mechanical parts must be installed and all ducting secured before applying mains power There are no isolated safety extra low voltag...

Page 4: ...system Do you have enough excess heat You may need to run your heat source at higher output levels Is your property well insulated Heat lost through poor insulation costs you money Background heating...

Page 5: ...ections Suspend the fan no more than 400mm above the roof insulation and ensure it does not make direct contact with any framing Secure the intake grille to ensure the system cannot suck up the roof i...

Page 6: ...se touch screen controller location Ensure the correct airflow direction is maintained when mounting the fan Once suitable hanging points for the fan have been found place the fan below its intended p...

Page 7: ...y down to the flush box Wire the cable to the power module of the touch screen controller located on the back Separate the front screen of the touch screen controller from the back module Carefully in...

Page 8: ...nd go to next setting option Screen Highlights Home Screen Icons 1 Heat Transfer mode selections are AUTO or MAN manual 2 When an electronic fault in the system occurs the alert icon will appear and t...

Page 9: ...ly Press HOME at any stage to exit and enter Scheduler Settings Press SETTINGS at any stage to return to the previous screen Select MONTH value Go to DAY DATE value Select DAY DATE value Save all TIME...

Page 10: ...temperatures correctly Controller is configured to match the number of speeds the fan motor has Fan operates on all speeds Put fan onto high speed to continue inspection There are no leaks in the duc...

Page 11: ...s guide must also be used to enter the password at setting 018 before settings 019 and above can be changed Press for 3 seconds Save ADVANCED SETTINGS Turn System OFF Enter ADVANCED SETTINGS Select Se...

Page 12: ...A 1 Do not change 021 Reserved N A N A 022 Reserved N A N A 023 Reserved N A N A 024 Fan Type N A N A 025 Number of Fan Speeds 1 3 3 026 Reserved N A 1 Do not change 027 Touch Activation Setting Home...

Page 13: ...ature Range 5 35 C adjustable Display Resolution 0 1 C Operating Voltage Frequency 220 240V AC 50Hz Switching Voltage 240V AC Max Switching Current 3A max resistive load Operating Temperature 0 to 40...

Page 14: ...15...

Page 15: ...PUB1672 2102 Ventair Pty Ltd 4 Capital Place Carrum Downs VIC 3201 Australia p 61 3 9775 0556 e info ventair com au w www ventair com au...

Reviews: