D. WIRING 

 

WARNING: THE MANI3000N AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED 
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. 

 

THE MANI3000N UNIT MUST BE EARTHED. 
 

 

Access to the MANI3000N connection terminals is under the top cover which is retained by four screws.  Ensure that 
the mains supply voltage, frequency, number of phases and power rating comply with the details on the rating label 
positioned under the top cover. 

 

All wiring must be in accordance with local and/or national electrical codes as applicable or the appropriate standard 
in your country (BS7671 in the UK).  The MANI3000N must be supplied through a double-pole isolating switch, having 
a contact separation of not less than 3mm. Cable clamps are provided for use with the cable or flex on entry into the 
MANI3000N. 
The MANI3000N has three speed settings.  Select the required speed and wire as indicated in Figure 1. 
 
Alternatively  the  MANI3000N  may  be  wired  in  a  number  of  different  ways  to  achieve  optimum  ventilation  control. 
Figure 2 shows a wiring diagram to provide 3-speeds selectable by a remote switch. 
  
Figure 3 shows a wiring diagram for automatic switching from medium to high speed using an external sensor. 
 
 

 

 

 

1.  Connect mains supply as (

Fig. 1

,2 or 3 below) 

2.  Check that all connections have been made correctly. Ensure that all terminal screws and cable clamps are 

securely fastened. 

3.  The cable entry must be made using a suitable grommet or cable gland. 
4.  Replace cover using the 4 screws provided. Switch the mains supply on and check the system is operating 

correctly. 
 

Fig.1. 
Permanent wiring for fixed speed 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MANI3000N

Page 1: ...PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Watt Manivent AC Whole house extract system Installation and Wiring Instructions MANI3000N IP22...

Page 2: ...an s rating label 6 When the fan extracts air from a room containing an open flue of a gas or fuel burning appliance precautions must be taken to avoid the back flow of gases into the room 7 The fan s...

Page 3: ...he other remaining LS input can be used to switch the unit to Purge speed B SITING DO NOT install this product in areas where the following may be present or occur Excessive oil or a grease laden atmo...

Page 4: ...t diameter The larger the better Avoid having any bends filters or other obstructions within 250mm of the fan inlets and outlet 1 Position the MANI3000N taking into consideration the position of the r...

Page 5: ...less than 3mm Cable clamps are provided for use with the cable or flex on entry into the MANI3000N The MANI3000N has three speed settings Select the required speed and wire as indicated in Figure 1 Al...

Page 6: ...6 Fig 2 Wiring for 3 speeds selectable by external switch Fig 3 Wiring for automatic switching from medium to high speed utilising an external sensor...

Page 7: ...ny obstruction leave for a short time for the motor to cool before reconnecting If this recurs Isolate the MANI3000N and call a service engineer F COMMISSIONING Select the speed needed based on the si...

Page 8: ...Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External 5 Internal 5 External...

Reviews: