Installation Instructions

 

Specifications are subject to change without notice  

Page 3

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

Inline Extraction Fan Kit - 125mm Standard Profile

INLINE EXTRACTION FAN KIT INSTALLATION AND ELECTRICAL CONNECTION MUST 

BE CARRIED OUT BY A REGISTERED ELECTRICIAN

BEFORE INSTALLING THE INLINE EXTRACTION FAN KIT, MAKE SURE YOU HAVE TURNED OFF THE MAIN 

ELECTRICITY SUPPLY. DO NOT TURN IT BACK ON UNTIL THE INLINE EXTRACTION FAN KIT IS FULLY

INSTALLED AND READY TO USE.

ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN ACCORDANCE

WITH THE LATEST WIRING RULES AS/NZS3000.

CAUTION

•  Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).
•  All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2017, or latest   
 

edition thereof.

•  Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all  
 

stated warranties.

•  When fitting through an external wall, and external grille must be fitted at all times.
•  Fan kits should only be installed by fixed wiring. A flexible cord should not be used.
•  This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and  
 

knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible  

 

for their safety.

•  Children should be supervised to ensure that they do not play with the fan.
•  In case of damage to the supply cord, switch off the device and do not tamper with it. Damaged supply cords must only be repaired or  

 

 

replaced exclusively by the manufacturer or by an appointed representative. Failure to comply with the above may endanger the safety of    

 

people and cause possible damage to the whole system.

•  The fan kit is to be installed so that the blades are more than 2.1m above the floor.
•  Exhaust fans may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow  
 

of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of an exhaust fan such as a partition  

 

fan or a duct fan the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases  

 

does not occur.

WARNING

•  This inline extraction fan kit is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials away    
 

from the fan kit and keep them away from the sides and rear.

•  Do not use near or in the immediate vicinity of a bath or swimming pool or any wet areas.
•  To protect against electric shock, do not immerse cord or plug in water or any other liquids.
•  Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fire or damage to the fan kit.
•  Do not put fingers or foreign objects into the grille while in operation.
•  Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all  
 

stated warranties.

•  To prevent overheating of this fan kit, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and  
 

outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.

•  Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
•  This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the  
 

nearest collection point. 

Summary of Contents for FAN5371

Page 1: ...lation within a shower cubicle The high performance fan provides high levels of extraction and enables additional ducting to be added to this system DIMENSIONS SPECIFICATIONS Duct mm Fan Type Max Fan...

Page 2: ...for ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventila...

Page 3: ...d exclusively by the manufacturer or by an appointed representative Failure to comply with the above may endanger the safety of people and cause possible damage to the whole system The fan kit is to b...

Page 4: ...AC Switch Switched Live 12VAC Extract a Lite 12VAC light FAN Existing Light 230VAC Existing Switch 12VAC Permanent Live Timer Model Standard Model 3 PERMANENT LIVE 2 SWITCHED LIVE 1 NEUTRAL 3 2 1 Neut...

Page 5: ...ternal grille select a suitable position either in the soffit or on an outside wall and cut a 130mm hole Attach one end of the flexible duct to the grille and from the outside feed the ducting through...

Page 6: ...djust the timer setting Rotate to the right to increase the time indicated by on the diagram Rotate to the left to decrease the time indicated by on the diagram Only adjust with power switched off All...

Page 7: ...on To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items...