Installation Instructions

 

Specifications are subject to change without notice  

Page 1

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

Inline Extraction Fan Kit - 125mm Standard Profile

Supply

Sound Level 

Max. Operating Temp

Ducting

220-240V AC, 50Hz

41 dB(A)

40°C

4m Flexible PVC

Thank you for purchasing this quality 125mm inline extraction fan kit.

To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference. 

When using electrical appliances, basic safety precautions should always 
be followed to reduce the risk of fire, electrical shock and personal injury.

This Manrose inline extraction fan kit is designed for ventilation within a shower 
cubicle. The high performance fan provides high levels of extraction and enables 
additional ducting to be added to this system. 

DIMENSIONS

SPECIFICATIONS

Duct

(mm)

Fan Type

Max.

Fan Watts

(W)

Max.

Fan Pressure

(PA)

Free Air Fan Performance

Specific

Fan Power

(W/l/s)

Interior Grille

Exterior Grille

(l/s)

(m

3

/hr)

125

Axial

20

35

36

130

0.56

Round White

EggCrate White

TECHNICAL

Compliance: AS/NZS60335-2.80:2016

C

A

B

E

D

A

C

B

E

D

G

F

H

Diffuser

Description

Product Code

with LED

Standard Switching

FAN5371

Timer

FAN5372

with Halogen Light

Standard Switching

FAN2037

Timer

FAN2038

LIGHT SPECIFICATIONS

Model

Output

Lamp

Beam Angle Max Output

Total Wattage

with LED

Driver 12V DC

12V 3W

25º

12W

23W

with Halogen Lamp

Transformer 12V AC

12V 50W

60º

60W

70W

Cut-Out Size

A

B

C

D

E

F

G

H

145

125

155

125

195

155

170

74

118

Note:

 

Diffuser cut-out size is a nominal diameter for a circular cut-out.

TECHNICAL

Summary of Contents for FAN5371

Page 1: ...lation within a shower cubicle The high performance fan provides high levels of extraction and enables additional ducting to be added to this system DIMENSIONS SPECIFICATIONS Duct mm Fan Type Max Fan...

Page 2: ...for ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventila...

Page 3: ...d exclusively by the manufacturer or by an appointed representative Failure to comply with the above may endanger the safety of people and cause possible damage to the whole system The fan kit is to b...

Page 4: ...AC Switch Switched Live 12VAC Extract a Lite 12VAC light FAN Existing Light 230VAC Existing Switch 12VAC Permanent Live Timer Model Standard Model 3 PERMANENT LIVE 2 SWITCHED LIVE 1 NEUTRAL 3 2 1 Neut...

Page 5: ...ternal grille select a suitable position either in the soffit or on an outside wall and cut a 130mm hole Attach one end of the flexible duct to the grille and from the outside feed the ducting through...

Page 6: ...djust the timer setting Rotate to the right to increase the time indicated by on the diagram Rotate to the left to decrease the time indicated by on the diagram Only adjust with power switched off All...

Page 7: ...on To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items...

Reviews: