WALL DOG PERFORMANCE DATA

PUB01548 2001

Ultimate and Allowable Load Capacities for Wall Dog in Normal Weight Concrete

1)

Anchor Diameter

(mm)

Minimum Embedded Depth

(mm)

Minimum Concrete Compressive Concrete Strength

(27.6 MPa)

Ultimate Load

Allowable Load

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

6.4

19.1

1.6

4.6

0.4

1.2

25.4

3.2

4.8

0.8

1.2

Ultimate and Allowable Load Capacities for Wall Dog in Normal Weight Concrete

2)

Anchor Diameter

(mm)

1/2” Wallboard

5/8” Wallboard

3/4” Wallboard

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

6.4

0.4

1.1

0.6

1.6

1.1

2.7

Ultimate and Allowable Load Capacities for Wall Dog in Wallboard and Plywood

3)

Anchor Diameter

(mm)

1/2” Wallboard

5/8” Wallboard

3/4” Wallboard

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

6.4

0.1

0.3

0.2

0.4

0.3

0.7

Ultimate and Allowable Load Capacities for Wall Dog in Grout-Filled, Hollow Concrete Masonry and Structural Brick Masonry

4)

Anchor Diameter

(mm)

Minimum 

Embedded 

Depth

(mm)

Anchor Location

Grout Filled Concrete Masonry 

ASTM C 90

Hollow Concrete Masonry 

ASTM C 90

Brick Masonry

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

6.4

19.1

Centre of 

Masonry Unit

-

-

-

-

1.8

2.9

19.1

T-Joint

-

-

-

-

1.6

2.7

25.4

Centre of 

Masonry Unit

1.3

3.7

1.4

3.7

2.7

4.1

25.4

T-Joint

1.3

4.1

1.3

4.1

1.7

3.7

Ultimate and Allowable Load Capacities for Wall Dog in Grout-Filled, Hollow Concrete Masonry and Structural Brick Masonry

5)

Anchor Diameter

(mm)

Minimum 

Embedded 

Depth

(mm)

Anchor Location

Grout Filled Concrete Masonry 

ASTM C 90

Hollow Concrete Masonry 

ASTM C 90

Brick Masonry

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

Tension (kN)

Shear (kN)

6.4

19.1

Centre of 

Masonry Unit

-

-

-

-

0.4

0.6

19.1

T-Joint

-

-

-

-

0.3

0.5

25.4

Centre of 

Masonry Unit

0.2

0.7

0.3

0.7

0.5

0.8

25.4

T-Joint

0.3

0.8

0.3

0.8

0.3

0.7

1) 

Allowable load capacities listed are calculated using an applied safety factor of 4.0.

2)  

The vales listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0  or greater to determine the allowable working load.

3) 

Allowable load capacities listed are calculated using an applied safety factor of 4.0.

4)  

The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load.

5) 

Allowable load capacities listed are calculated using an applied safety factor of 5.0.

Summary of Contents for FAN2303

Page 1: ...ry Wall fans are designed to move air efficiently over long distances in residential and light commercial applications where high performance and low noise is required A B C 305 110 369 DIMENSIONS SPE...

Page 2: ...ion The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventilation in acco...

Page 3: ...upply cords must only be repaired or replaced exclusively by the manufacturer or by an appointed representative Failure to comply with the above may endanger the safety of people and cause possible da...

Page 4: ...Green Yellow P N E 2 0 F CAP Motor White For centrifugal 3 speed inline fan models FAN2317 WIRING CONNECTIONS SP3 P SP2 P SP1 P N E White 3 White 2 White 1 White 4 Green Yellow Motor 2 0 F CAP White...

Page 5: ...a 125mm 150mm reducer not supplied to fit other sizes of duct 7 Ensure that there is sufficient space for the product to be installed and that the front cover can be removed for maintenance 8 Confirm...

Page 6: ...Concrete Masonry ASTM C 90 Hollow Concrete Masonry ASTM C 90 Brick Masonry Tension kN Shear kN Tension kN Shear kN Tension kN Shear kN 6 4 19 1 Centre of Masonry Unit 1 8 2 9 19 1 T Joint 1 6 2 7 25...

Page 7: ...for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items such as lamps and starters and c damage arising from...

Reviews: