NEUTRAL IN
LIVE IN
NEUTRAL IN
LIVE IN
NEUTRAL IN
INPUT ONLY IN
EXTRACT ONLY IN
LIVE IN
EXTRACT ONLY
INPUT ONLY
REVERSIBLE SPEED CONTROLLER
Plug Wiring Diagram
Diagram A
Diagram B
Diagram C
WIRING DIAGRAM
DIAGRAM A - EXTRACT ONLY
To change the airflow direction remove link from terminal 1 in the plug and connect into terminal 2.
DIAGRAM B INTAKE ONLY
All models are pre wired in factory to extract only. When the cable supplied with the socket for test purposes is
connected to a fused spur or plug socket.
DIAGRAM C - REVERSIBLE SPEED CONTROLLER
For the COMTK 230/300 models using the reversible variable speed controller part no. COMTSCVR.
7. Electrical
220-240V AC.50HZ IP44 T. Max 40 deg C
COMT/COMTK 150 - 25W
COMT/COMTK 230 - 48W
COMT/COMTK 300 - 60W
THIS FAN SERIES IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH. THE EARTH TERMINAL IS
PROVIDED FOR SPECIAL INSTALLATIONS ONLY.
NOTE:
Do not install within a shower cubicle (Use our SF100, SF120, SF150 range of shower fans) or anywhere else where
there is a high risk of the fan being sprayed with water.
Fan to be fitted a minimum 2.3 metres from the floor.
077311 06/15