Manning MSP250 Operation Manual Download Page 11

 

Specifications 

 

 
Size ....................................... Controller, including Pump Housing: W 12.5 in. (31.75 cm) 

×

 H 7.00 in. (17.78 cm) 

×

 D 10 in. (25.4 cm) 

Weight (dry) ........................... 10 lbs (4.54 kg).  Weight includes battery. 
Environmental Protection ....... NEMA 4X/NEMA 6 structural resin housing around electromechanical components 
Sampler Pump ....................... ¼-inch peristaltic 12 VDC pump with impact and corrosion-resistant plastic pump body, and dual-roller 

mechanism 

Maximum Lift ......................... 28 ft (8.5 m) 
Transport Velocity .................. 927 ml per minute @ 10 ft. head height 
Power Requirement ............... 12VDC 8-Amp hour battery 
Warranty: ............................... One year from date of shipment. 

 

Accessories

 

MSP250 Manual Sampling Pump* Spare Parts/Accessories 

 

• 

Replacement Pump Tubing 

¼-inch Pharmed (pre-cut 18-inch length) P/N 889924 
¼-inch Pharmed (bulk by the foot) P/N 566927 

 

• 

Replacement

 

Battery 

Standard 8-Amp hour battery P/N 690539 

 

• 

Battery Charger 

Standard-output  3-stage Charger (12 VDC @ 750 mA; for 110/220 

VAC operation) P/N 885400* 

 

• 

Hose Couplings 

Female P/N 552113 
Male P/N 5521112 

 

• 

Intake Hose 

¼-inch bulk clear intake hose P/N 566926 

Please specify required length in feet. 

 

• 

Sample Containers 

One 2.5-gallon polyethylene bottle w/cap P/N 687547 
One 4-gallon polyethylene bottle w/cap P/N 687551 
One 5-gallon polyethylene bottle w/cap P/N 687535 
One 2.5-gallon glass bottle w/Teflon lid liner P/N 889715 
5-gallon polyethylene pail with splashguard & transport lid  

P/N 889721 

 

• 

Strainers 

¼-inch PVC P/N 889146 
¼-inch stainless steel P/N 579595 

 

 

*  Basic sampler includes one (1) 8-amp hour battery, one (1) standard-output battery charger, one (1) 18” pre-cut length of pump tubing with 

a set of male and female hose couplings attached, and one (1) additional set of hose couplings (male & female).  Bottle, intake hose, and 
strainer are additional. 

 
Engineering

 

Specification

 

 

 

1.  The controller enclosure is made of 

structural resin with NEMA 4X/NEMA 6 
ratings. 

2.

  All wetted parts have a minimum internal 

diameter of ¼-inch, and are stainless steel 
or PVC (optional strainer), PVC (sampling 
hose), and Pharmed (pump tubing).

 

3.  The sampler incorporates a 3-roller ¼-inch ID 

peristaltic pump 

4.

  The sample liquid must be under forced flow at 

all times and shall not pass through a metering 
chamber, distribution plate, or valves.  . 

 

5.

  The sampler is capable of a transport velocity 

of 927 ml per minute @ 10 ft. head height.

 

6.  The sampler has an optional weighted 

strainer of PVC or stainless steel. 

7.  Sampler is suitable for 110 or 220V 

operation with standard battery 
charger. 

8.  This sampler is a Manning ¼-inch 

MSP250 Manual Sampling Pump. 

 

MSP250 Manual Sampler 04/24/2012 

 

For parts and service, please contact:  Manning Environmental Tech Support (800) 863-9337 x 205  

or email 

[email protected]

 

 

Headquarters and Sales: 

 

Manning Environmental, Inc

101 Bar T Drive

 

Florence, Texas 76527-4445 

Phone

:

  (

800) 863-9337 

Fax

:  (254) 793-9965 

Email:  

[email protected]

 

Web:

 

http://www.manningenvironmental.com

 

In the interest of improving and updating its equipment, Manning reserves the right to alter specifications for equipment at any time.

Summary of Contents for MSP250

Page 1: ...MSP250 Manual Sampling Pump Operation Manual 17 April 2014 2014 Manning Environmental Inc All rights reserved...

Page 2: ......

Page 3: ...e pointing upward lay case flat and run pump to completely clear fluid from lines or spatter may occur 3 Keep inside of electronics enclosure and battery dry at all times Replacing Pump Tubing The pum...

Page 4: ...e side that fits against the case is pointing upward 5 Orient rollers in of pump housing as in picture Note roller position 6 Fold pump hose in half aligning ends and forming loop at other end 7 Place...

Page 5: ...kit rotate rollers clockwise while pressing hose in gap between rollers Note Pump tool is stored in a slot at the top left of the foam insert in case 9 Continue until hose is in place 10 Once hose is...

Page 6: ...emoving Hose Fittings Hose This procedure is for installing and removing the quick disconnect fittings used on units manufactured before May 2012 from the ID PVC intake hose It is also applicable for...

Page 7: ...f round nose pliers into the end of the hose 3 Stretch out the hose with the pliers Rotate the pliers 90 degrees in the hose and stretch again 4 Quickly remove the pliers and insert the fitting into t...

Page 8: ...s the fitting into the hose using a wiggling motion 6 Make sure that barbed end of fitting is fully inserted into hose Removal of fitting 1 Using a knife cut a slit in the hose along the side of the c...

Page 9: ...vailable from Manning as an accessory Intake hose should always be internal diameter If a larger internal diameter hose is used the coupling may not fit and there will be a loss of performance In May...

Page 10: ...ing recommends using a strainer on the intake hose to prevent clogging Strainers are available from Manning in PVC or stainless steel If you have any questions please call Manning Technical Support at...

Page 11: ...tainless steel P N 579595 Basic sampler includes one 1 8 amp hour battery one 1 standard output battery charger one 1 18 pre cut length of pump tubing with a set of male and female hose couplings atta...

Page 12: ...ation 3 Damage caused by any repair attempted repair or modifications not authorized by Manning Environmental Inc 4 Any product not used in accordance with the instructions furnished by Manning Enviro...

Reviews: