MANN+HUMMEL TRIDIM Tri-Lock GS Operation & Maintenance Manual Download Page 8

Appendices

 

One last thing...

APPENDIX A

It is recommended that the buyer supply complete information 
about the operating conditions of the ventilation system prior to 
installation of any HEPA side-access filter housing. 

Location-specific conditions may prevent the system from 
operating satisfactorily in certain applications. 

Any non-factory alterations to the product may result in a 
compromised installation. 

Please contact the manufacturer for any questions not addressed 
in this manual.

APPENDIX B – LOCKING TRAY CHANGE OUT

It is advised that any locking-tray mechanism replacement or 
change out be done in a decontaminated environment. One of the 
advantages of the Tri-Lock FS/GS housings is the ability to change 
out locking trays in the field.

Change out is a simple task. The same concept that applies to 
filters applies to locking mechanisms—refer back to the Start-Up 
Procedures.

First, remove all filters from the contamination unit following the 
aforementioned Start-Up Procedures.

Fluid Seal Method

1.

  Using the ratchet with a ½” socket, remove the two hex nuts and 

washers for both the top and bottom locking trays.

2.

  Then switch to a ⅜” socket, and remove the hex nut and washers 

from the linkage to the door swing arm.

3.

  Remove both the top and bottom parts to each pair of locking 

trays. 

4.

 Treat the locking mechanism as a dirty filter and continue the 

appropriate steps.

Gasket Seal Method

1.

  Using a ratchet with a ½” socket, remove the two hex nuts and 

washers for both the top and bottom locking trays.

2.

  Lift the top half of each locking tray off the studs and into the bag.

3.

 Remove the pipe bearings from the locking mechanism and 

back off the drive bolts to release the bottom locking trays.

4.

  Remove the bottom-locking tray.

5.

 Treat the locking mechanism as a dirty filter and continue the 

appropriate steps.

tridim.com

mann-hummel.com

Tel: 800-458-9835 

[email protected]

2500-15 0920 © MANN+HUMMEL GmbH

LOCAL REPRESENTATIVE

Tri-Dim Filter Corporation is committed to continual product 
development – all descriptions, specifications and performance 
data are subject to change without notice. Tri-Dim products are 
manufactured to exacting criteria – there can be a ±5% variance 
in filter performance. 

Summary of Contents for TRIDIM Tri-Lock GS

Page 1: ...Tri Lock GS FS Operation Maintenance Manual...

Page 2: ...TION AND MAINTENANCE Tri Lock Operation Maintenance CONTENTS Introduction 3 Application 3 Performance 4 Handling and Storage of Filter Elements 6 Installation of New Housings 6 Start Up Procedures 7 A...

Page 3: ...nnel and no extrusion Hat sections are located on the top bottom and back of the unit for structural support Each housing is custom manufactured to meet specific end user requirements The unit is cons...

Page 4: ...echanism guides and secures the filter into the knife edge penetrating the gel and forming a positive seal on the filter face DESCRIPTION OF FLUID SEAL FILTER LOCKING SYSTEM The fluid seal Tri Lock FS...

Page 5: ...or each filter element apply consistent pressure to maintain the filter seal The applied force has a minimum clamping load of 1 400 pounds per perimeter of the filter The gasket on the filter is compr...

Page 6: ...r than 0 F or higher than 100 F Stacking of filters is not recommended Movement of filters should be restricted to reduce the chance of damage to the media Any additional filter manufacturer s instruc...

Page 7: ...e Option lift the door off the hinge and place in a safe location 4 Unseal the filter Pull the arm all the way outward to the open position The mechanism will pull the filters from the gel track via e...

Page 8: ...eal Method 1 Using the ratchet with a socket remove the two hex nuts and washers for both the top and bottom locking trays 2 Then switch to a socket and remove the hex nut and washers from the linkage...