Introduction 

Installation and maintenance 

 

Requirements for the installation site

 

ProVent² 500 can be mounted on the engine or frame of the machine / vehicle.  

Inlet connection to the engine

  

The blow-by gases reach the ProVent² 500 via the inlet nozzle. Possible extraction points for the blow-by gas 

must be in an area with a low oil content. These are areas in which there are no moving parts and no splash oil 

is present, e.g. upper areas of the crankcase or the cylinder head cover. 

This crankcase outlet must be connected to the ProVent² 500 system inlet port.  

 

Connection principles Oil return 

Connection below oil level  

The oil return is connected to the engine via a drainage pipe below the minimum permissible oil level of the oil 

pan. When the engine is switched off (no blow-by gas), the same oil level is present in the oil pan and the 

drainage pipe. 

When the engine is running, this oil trap acts like a siphon so that the blow-by is led over the oil separator when 

the oil is sucked out of the outlet nozzle. The differential pressure of the oil separator determines the height of 

the oil column in the oil return line. If an oil separator element is installed in the system, the same negative 

pressure is present in the oil return line during operation as at the oil separator. These relationships must be 

taken into account when selecting the installation location. 

Connection above oil level  

This connection variant requires an optionally available non-return valve. The valve is installed in the drainage 

pipe as close as possible to the oil level (approx. 30 to 50 mm above maximum oil level).  

During operation, the separated oil accumulates above the non-return valve. During operation, the check valve 

is closed by the differential pressure of the separator. If the weight of the oil column exceeds the closing 

pressure of the valve, or after switching off the engine, the separated engine oil flows back into the oil pan. 

Any inclined positions that may occur in mobile applications that lead to a fluctuating oil level must always be 

taken into account. MANN+HUMMEL generally recommends the use of a check valve for all ProVent 

installations. 

Outlet within closed systems  

The outlet nozzle is connected to the engine intake (after the air filter, but before the turbocharger, if fitted). The 

highest possible point above the oil level or non-return valve must be selected as the installation location, but at 

least 350 mm for the standard separator element. 

The suction vacuum present during operation of a closed system sucks the blow-by via the respective ProVent² 

500 and returns the cleaned blow-by gas to the intake tract of the engine. When selecting the installation 

location, the type of oil return must be taken into account.  

Outlet within open systems 

The outlet nozzle remains open. The cleaned blow-by gas is discharged into the open air.

 

 

Summary of Contents for ProVent2 500

Page 1: ...Leadership in Filtration MANN HUMMEL ProVent 500 Installation and maintenance instructions...

Page 2: ...pment Usage Ordinance the operator is responsible for providing work equipment that meets the basic safety and health requirements This also includes using these work equipment in such a way that it i...

Page 3: ...omplies with the basic national safety and accident prevention regulations This also includes using these working and protective equipment only within the scope of its intended use Always ensure suffi...

Page 4: ...seller immediately Install the filter system so that vibration temperature and humidity e g splash water or rain cannot damage the application or the components of the filter system When working on th...

Page 5: ...uthorized personnel are authorized to service the filter system The operator is obliged to check the filter system once a week for externally recognizable damage and defects and to immediately report...

Page 6: ...pan and is thus available to the oil circuit again The formation of blow by gases Combustion gases so called blow by gases between piston rings and bushings enter the crankcase at each working stroke...

Page 7: ...ccount when selecting the installation location Connection above oil level This connection variant requires an optionally available non return valve The valve is installed in the drainage pipe as clos...

Page 8: ...ment or service of the element LC 14 002 as shown below must be carried out according to the manufacturer s specified service intervals or according to requirements No other repair of the ProVent 500...

Page 9: ...ata sheets of the corresponding filter material Technical data of the filter system according to the quotation drawing Operating and maintenance instructions of the application manufacturer National s...

Page 10: ...www mann hummel com 1961130002 0420 Printed in Germany MANN HUMMEL...

Reviews: