6 – EN
EN – 7
EN
OurAir SQ 500
Operation notes
2.2 Technical details
Purifying technology
HEPA H14 filters acc. ISO 29463 & EN 1822
Filter material
Multilayer ePTFE-membrane media
Air flow volume
500 m³/h
Max. power consumption
85 W
Gross weight
11.3 kg
Measurements
0,44 m x 0,28 m x 0,65 m
3 Operation notes
3.1 Before Use
3.2 Usage Environment
- Remove the protective packaging of the HEPA filter element before use.
To do this, remove the filter element from the unit (see chapter 5) and then reinsert it properly.
- Before connecting the plug to a wall outlet, check that the mains voltage is correct.
Observe the information on the type plate of the device.
- If the supply cable is damaged, it must be replaced by the manufacturer, his service staff
or similarly qualified persons to avoid any danger. Do not repair the device yourself.
- Turn off the unit when cleaning or putting it away. When not in use, always unplug the device
(pull the plug itself, not the cable) and remove any accessories connected to it.
- Never operate the unit in a room where explosive gas can accumulate. There is a risk of explosion
if solvent or gasoline leaks.
- Never place burning objects (such as candles, cigarettes, etc.) near the device, otherwise there is
a risk of damage or even fire.
- Never operate the device in a room with high humidity and high ambient temperature, e.g. in a
bathroom, shower or swimming pool, toilet or kitchen, as moisture can accumulate in the device
and cause an electric shock.
- Never add aromatic oil to the filter.
- Operate the device only at room temperatures between 0°C and 40°C.
- Always place and use the air purifier on a dry, stable, level, and horizontal surface.
- Leave at least 20 cm free space behind and on both sides of the air purifier and leave at least
30 cm free space above the air purifier.
- Do not place anything on top of the air purifier.
- Do not place the air purifier directly below an air conditioner to prevent condensation from
dripping onto the air purifier.
- Do not use the air purifier in a room with major temperature changes, as this may cause
condensation inside the air purifier.
- Never place the unit directly next to stoves, other heat sources, gas appliances or fireplaces.