OPERATIONAL  NOTES

SWITCHING ON
The power switch is located on the lower right hand corner of the front panel.  Push the top of the
rocker switch (1) to turn on the amplifier and the bottom of the rocker to turn off the amplifier.

With monoblocks we suggest that you turn on one amplifier first allowing about thirty seconds to pass
before powering the other one.  Also, ALWAYS turn ON your preamplifier or consule FIRST and let
this settle before turning on the amplifiers.

RUNNING
It is not recommended that you leave your amplifier permanently switched on.  This only wastes
electricity and tube life.  Your amplifier has solid state rectification and reaches peak operating
condition in approximately 30 minutes.

TUBE LIFE
As with all tubes, their quality degrades with age.  This is due to cathode emission, a natural process
found in all tubes.  We recommend that you have your amplifier checked every 3-4 years, depending
on usage, usually the amplifier will require re-tubing after this time has elapsed.

Summary of Contents for STUDIO STANDARD 350

Page 1: ...MANLEY LABORATORIES INC OWNER SMANUAL STUDIO STANDARD 350 WATT MONOBLOCK AMPLIFIER...

Page 2: ...3 MAINS CONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 FIGURE1 FRONTPANEL 6 FIGURE2 TOPPANEL 7 FIGURE3 REARPANEL 8 BIASPROCEDURES 9 OPERATIONAL NOTES 10 SPECIFICATIONS 11 WARRANTY 12 WARRANTY REGISTRATION 13...

Page 3: ...tilation openings We also recommend that the amplifier if driven by a preamplifier be placed at least 10 inches apart Do not place amplifiers directly on high pile carpet or any other surface that wil...

Page 4: ...which is coloured GREEN YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN and YELLOW The wire which is colo...

Page 5: ...ttom binding post See diagarm III Ensure that the other end of the cable is connected correctly to the speaker Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the pos...

Page 6: ...uence and the bias adjust pots used to alter the bias of each tube 4 The first step to setting the bias is to turn on the amplifier and ensure that there is zero signal input Also leave your loadspeak...

Page 7: ...or consule FIRST and let this settle before turning on the amplifiers RUNNING It is not recommended that you leave your amplifier permanently switched on This only wastes electricity and tube life Yo...

Page 8: ...MINIMUM 0 97 dB slope STANDARD 0 88 dB slope MAXIMUM InputSensitivity Full power feedback MAX 1 8 Vrms STAND 1 44 Vrms MIN 1 2 Vrms InputImpedance 82 Kohm LoadImpedance 5 ohm 2 5 ohm S N Ratio 350W fe...

Page 9: ...rwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutcharge...

Page 10: ...SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL ____________________ SERIAL No ______...

Page 11: ...NOTES...

Reviews: