background image

INTERNAL ADJUSTMENTS

1

2

7

4

5

9

10

6

8

3

1)

+36 Volt DC adjust with meter from ground to resistor marked by arrow. Check this first and adjust if
needed. It is the power supply regulator adjustment. Now for the audio ....
You will have to start out by setting front panel controls to these settings. BYPASS mode, SEP (
LINK OFF ), REDUCTION controls counter clockwise (MIN), GAIN to 1:00 or unity, Balance
at 12:00. The top will need to be open. There are two screws on the top that hold the top perforated
panel to the back. Remove these and the perforated top will slide back. Be careful! THERE ARE
HIGH VOLTAGES INSIDE THE LIMITER. DO NOT HOLD THE METAL PART OF THE
SCREWDRIVER. DO NOT PROBE AROUND WITH THE SCREWDRIVER OR FINGERS. The
unit should be on for about 15 minutes to allow for "warming up".

2 & 3)

This adjusts theamplifier gain in all modes. 1 KHz sine at 1.23 volts RMS (+4 dBm, 0 VU) to
both inputs. BYPASS mode. Adjust 2 & 3 for unity gain at outputs.

4 & 5)

This adjusts VU meter calibration for OUTPUT. Same input, Meter switches to OUTPUT. Adjust for
0 VU on the Meters.

6 & 7)

This adjusts the meter zero for Reduction mode. Meter switches to REDUCTION. Adjust for 0 VU on
the Meters.

8 & 9)

This adjusts the meter in Reduction mode to reflect the actual gain reduction accurately. You will
probably need to increase the oscillator 10 dB to get Limiting. Switch from BYPASS to IN. Meter
switches to OUTPUT. Adjust GAIN controls to get 0 VU on the METERS again, then adjust
REDUCTION controls to reduce the signal to -4dB. Switch METERS to REDUCTION. Adjust 8 &
9 to get -4 dB on the METERS.

10)

This adjusts the gain of the right side chain and adjusts the side chain balance in Link. Switch the
LINK ON. There should be 1 to 2 dB change in the Meters. Adjust 10 so that the meter is the
same for both sides. You may have to re-adjust 8 and 9. Check that both in LINK and
SEPARATE that both channels show the same reduction.

This is a final check to verify that all adjustments are OK and the unit is ready for use. Confirm that 0
VU on the meters is +4 dBm with an external VU meter or VOM  that reads between 1.22 and 1.23
volts AC and that gain reduction reads the same on OUTPUT and REDUCTION and that LINK or
UN-LINK does not reduce the gain unevenly on the two sides. Remove the power and slide the top in
all the way where it will fit into a groove in the front panel and put those two top screws back in.
Done !

Summary of Contents for Langevin ELOP

Page 1: ...S MANUAL LANGEVIN ELECTRO OPTICAL LIMITER MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 TEL 909 627 4256 FAX 909 628 2482 email emanley netcom com http www manleylabs com MANLEY LABORATORI...

Page 2: ...NTENTS SECTION PAGE INTRODUCTION 3 MAINS CONNECTIONS 4 OPERATION NOTES 5 6 FRONT PANEL 7 REAR PANEL 8 TROUBLE SHOOTING 9 10 INTERNAL ADJUSTMENTS 11 SPECIFICATIONS 12 WARRANTY 13 WARRANTY REGISTRATION...

Page 3: ...unreliable We also use a solid state side chain to drivetheLEDs TheLimiteralsofeaturesaBYPASSswitchthatretainsthetubesectionatunitygain as well as an innovative BALANCE control to fine tune the stereo...

Page 4: ...king identifying the terminals in your plug proceed as follows The wire which is coloured GREEN YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety ea...

Page 5: ...se our Langevin line amplifier circuit which we also use in the Langevin Enhanced Pultec Equalizers rather than copy UREI designs because frankly our circuit sounds better and cleaner Back to this mat...

Page 6: ...able tone of the drum is diminished If used gently this can be applied to brighten up the attack of the drum but it is difficult to apply in practice because drums can be very dynamic One great use is...

Page 7: ...ikely the limiting will be audible Switch to OUTPUT to show the output level as a conventional VU meter E METER Shows the amound of gain reduction in dB from the 0 dB mark Functions as a high quality...

Page 8: ...IN 1 GROUND PIN 2 HOT PIN 3 GROUND H 1 4 INPUT BALANCED LEFT TIP HOT SLEEVE GROUND I XLR OUTPUT BALANCED RIGHT PIN 1 GROUND PIN 2 HOT PIN 3 GROUND J 1 4 INPUT UNBALANCED RIGHT TIP HOT SLEEVE GROUND Us...

Page 9: ...happens you will only be getting 1 2 the signal which means that you lost 6 dB There is a trick if you just want to use the XLRs but from time to time feed unbalanced inputs Insert a 1 4 mono tip slee...

Page 10: ...pegs the meters Some of you know already what s going on That 6 level is referenced to digital full scale and the computer might have 18 or 18 5 or 20 dB of headroom built in That 6 level on the oscil...

Page 11: ...eduction mode Meter switches to REDUCTION Adjust for 0 VU on the Meters 8 9 This adjusts the meter in Reduction mode to reflect the actual gain reduction accurately You will probably need to increase...