Manley 200 WATT MONOBLOCK AMPLIFIER Owner'S Manual Download Page 3

INTRODUCTION

THANK YOU!...
for choosing the Manley 500/200 Monoblock Amplifiers.  Designed by David Manley, the Manley 500/
200  Monoblock Amplifiers use only the best available components, with the shortest and cleanest
signal path possible, and with the use of our own in-house CNC machine shop we can provide you with
a amplifier that looks as good as it sounds.

The circuit and the components used have been chosen carefully after years of development and
refinement for reliability, constancy and most importanly, musical, accurate, and emotional delivery of
the sound. The circuit topology is similar to other designs in the MANLEY range. This amplifier is
configured to switch between triode or tetrode operation which allows the user to choose between the
sonic benefits and seductive qualities of triode and the more powerful tetrode operation mode. We
emphasize big, beefy resevoir capacitors in the high voltage supplies giving plenty of instant energy for
dynamic performance of transient peaks and bass performance which often exceeds that of rival solid-
state amplifiers. We run high voltages on the plates of the output tubes and are thus able to run them at
lower current which will result in longer life for the output tubes. Careful use of the 'EVER-WARM'
power switching should also greatly increase the life of the output tubes as well as allow your
amplifiers to always be ready for pleasurable listening. Each output tube has its own bias adjust, and the
procedure for adjusting each tube's current draw is described in this manual. The FEEDBACK &
SLOPE controls featured on the 500/200 allow the user to optimise the amplifier-speaker interface.

 The output transformer is a revolutionary new design by David Manley which is wound on the Manley
Labs factory premesis. Its stellar performance will be obvious upon first listening. The secret is in
keeping both phases of the push-pull halves always equal, and in this new output transformer design,
David has achieved just that. The output transformer has been factory set for an optimum 5 ohm load
which will drive most speakers.
Thank you again, and please enjoy!

Summary of Contents for 200 WATT MONOBLOCK AMPLIFIER

Page 1: ...MANLEY LABORATORIES INC OWNER S MANUAL MANLEY REFERENCE 500 200 WATT MONOBLOCK MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 USA TEL 909 627 4256 FAX 909 628 2482 email emanley netcom com...

Page 2: ...ON 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM TOP VIEW 6 DIAGRAM REAR VIEW 7 DIAGRAM FRONT VIEW 8 BIAS PROCEDURES 9 OPERATIONAL NOTES 10 SPECIFICATIONS 11 WARRANTY 12 WARRANTY REGISTRAT...

Page 3: ...ynamic performance of transient peaks and bass performance which often exceeds that of rival solid state amplifiers We run high voltages on the plates of the output tubes and are thus able to run them...

Page 4: ...amplifier into the mains socket Furthermore do not touch the tubes after the amplifier has been switched on as the tubes become very hot during operation and should only be handled after the power has...

Page 5: ...the common or speaker cable to the black binding post Ensure that the other end of the cable is connected correctly to the speaker Tighten the binding posts by hand If you use a nut driver 3 8 do not...

Page 6: ...ised around this tube Use of unapproved tube types can and will void your warranty DRIVER TUBES 2 x 6414 The 6414 is an American military uprated version of the 12BH7A with increased current drive INP...

Page 7: ...SPEAKER OUTPUT BINDING POSTS XLR BALANCED INPUT UNBALANCED BALANCED UNBALANCED BALANCED SELECT RCA UNBALANCED INPUT B FUSE SLO BLO MAINS FUSE SLO BLO MAINS IN IEC REAR VIEW...

Page 8: ...ERATE STANDBY EVER WARM SOFT START SWITCH TRIODE TETRODE SWITCH POWER LED STANDBY LED BLINKING TRIODE TETRODE MANLEY DESIGNERS REFERENCE SERIES 500 200 WATT MONOBLOCK DESIGNED BY DAVID MANLEY Handcraf...

Page 9: ...nd corresponds to the second from the left adjustment pot and so on 3 The first step to setting the bias is to turn on the amplifier and ensure that there is zero signal input either leave the preampl...

Page 10: ...sweet seductive sound of triodes For some more demanding energetic music large rooms or for power hungry inefficient loadspeakers you might find you will need the extra power of tetrode operation Othe...

Page 11: ...requency Response 5 dB 10 Hz 80 KHz Input Sensitivity 1V Input Impedance 100 KOhm Load Impedance 5 Ohm fixed S N Ratio 440W 80 dB Power Consumption 30 Watts Quiescent STANDBY MODE 1320 Watts Full Powe...

Page 12: ...rwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutcharge...

Page 13: ...AL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL MANLEY REFERENCE 500 200 MONOBLOCK SERIAL...

Reviews: