Manley 100 WATT STEREO AMPLIFIER Owner'S Manual Download Page 3

INTRODUCTION

!

THANK YOU!...
for choosing the Manley Euro 100 Stereo Amplifier.  Designed by David Manley, the Manley Euro 100 Stereo
Amplifier uses only the best available components, with the shortest and cleanest signal path possible, and with the
use of our own milling equipment we can provide you with a amplifier that looks as good as it sounds. For this
amplifier design, we have chosen an interesting Russian military tube, the GammaY50. The circuit and the
components used have been chosen carefully after years of development and refinement for reliability, constancy
and most importanly, musical, accurate, and emotional delivery of the sound. The circuit topology is similar to
other designs in the MANLEY range. This amplifier is configured for ULTRALINEAR or "partial-triode"
operation which achieves the seductive quality of triode operation without the inefficiency and sacrifice in power
of triode operation. We emphasize big, beefy resevoir capacitors in the high voltage supplies giving plenty of
instant energy for dynamic performance of transient peaks and bass performance which often exceeds that of rival
solid-state amplifiers. We run high voltages on the plates of the output tubes and are thus able to run them at lower
current which will result in longer life for the output tubes. Each output tube has its own bias adjust, and the
procedure for adjusting each tube's current draw is described in this manual. The output transformer has been
factory set in series-parallel for an optimum 5 ohm load which will drive most speakers. Other output impedances
can be achieved by changing the configuration of the transformer secondary. Please contact us at the factory should
you need to do this.

Thank you again, and please enjoy!

GENERAL NOTES

LOCATION & VENTILATION
The Manley  Stereo 100 Amplifier must be installed in a stable location with ample ventilation.  Allow a minimum
of 2 inches of clearance on the top and sides of the amplifiers, such that constant movement of air can flow.   Do
not place amplifiers directly on high pile carpet  or any other surface that will block the ventilation holes
underneath the amplifiers. If you have small children or pets, you should consider placing the amplifiers out of
reach or using the optional cages (covers) available as an option to prevent damage to the amplifier or damage to
your small children or pets by the amplifier as the tubes do get hot during operation.

WATER & MOISTURE
As with any electrical equipment, this amplifier should not be used near water or moisture.  If liquid enters the
amplifier, it must be immediately returned to your deal for servicing.

SERVICING
The user should not attempt to service the amplifier beyond that described in the owner's manual.  Refer all
servicing other than biasing and tube replacement to Manley Laboratories

SPECIAL NOTES
Tubes may become loose during transit.  Straighten and press down each tube before plugging the amplifier into
the mains socket.  Furthermore, NEVER touch the tubes after the amplifier has been switched on, the tubes become
very hot during operation and should only be handled after the power has been turned off and the tubes have

cooled.

WARNING!

TO PREVENT THE RISK OF ELECTRIC SHOCK

DO NOT OPEN THE CABINET

REFER SERVICING TO

QUALIFIED PERSONEL

Summary of Contents for 100 WATT STEREO AMPLIFIER

Page 1: ...MANLEY LABORATORIES INC OWNER SMANUAL MANLEY 100 WATT STEREO AMPLIFIER MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 TEL 909 627 4256 FAX 909 628 2482 ...

Page 2: ...CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 BIAS PROCEDURES 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10 SECTION PAGE ...

Page 3: ...ost speakers Other output impedances can be achieved by changing the configuration of the transformer secondary Please contact us at the factory should you need to do this Thank you again and please enjoy GENERAL NOTES LOCATION VENTILATION The Manley Stereo 100 Amplifier must be installed in a stable location with ample ventilation Allow a minimum of 2 inches of clearance on the top and sides of t...

Page 4: ...NEUTRAL terminal BROWN LIVE terminal As the colours of the wires in the mains lead may not correspond with the coloured marking identifying the terminals in your plug proceed as follows The wire which is coloured GREEN YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN and YELLOW The wire which is coloured B...

Page 5: ... cable to the black binding post See diagarm 2 Ensure that the other end of the cable is connected correctly to the speaker Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the posts or you may breaak the connection inside the amplifier 4 Ensure that the mains switch on the front panel is in the off or 0 position 5 Turn on Preamplifier and any source components you...

Page 6: ... output It is recommended that you leave the amplifier on long enough to ensure that the tubes have reached their stable current draw 5 Place the probes in the first black tip jack negative probes remains in the green tip jack for whole biasing proceedure and adjust the first bias trip pot see diagram 2 until you measure 300 to 350 mV Since you are measuring across a 10 ohm cathode resistor this w...

Page 7: ...e recommend that you have your amplifier checked every 3 4 years depending on usage usually the amplifier will require re tubing after this time has elapsed PANEL LAMP The lamp which illuminates the front panel insert is easily replacable should it ever burn out To replace it use only the same type with the same or greater voltage rating In these amplifiers the lamp is a FUSE LAMP STYLE 8V 0 15mA ...

Page 8: ...into 5 ohms Frequency Response 5 dB 10 Hz 35 KHz Input Sensitivity 800 mV Input Impedance 100 KOhm Load Impedance 5 Ohm S N Ratio 350W 80 dB Power Consumption 220 Watts Quiescent 420 Watts Full Power Mains Fuse 100 110 120V 6 A Slo Blo 220 240 V 3 A Slo Blo B Fuse 1A Dimensions W 19 D 13 H 7 inches Weight 46 lbs ...

Page 9: ...urwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutchargeforpartsandlabour Theproductwillthenbereturnedviaprepaid insuredfreight methodandcarriertobedeterminedsolelybyManleyLaboratories Allreturnstothefactorymust beintheoriginalpacking newpackingwillbesupp...

Page 10: ..._ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL ____________________ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER _______________________ NAME OF OWNER _______________________________________________ ADDRESS __________________________________________________...

Reviews: