background image

 16.08.2013     

 3

Scope of delivery and assembly

Dosing

MANKAR HQ 20

at a walking speed of 4 km/h and 20 °C Roudup PowerFlex

applied

Pre-position

Droplets per

ml per

quantity desired metering knob

minute

minute

1l / ha

A

33

1,3

2l / ha

A-B

67

2,7

3l / ha

B

100

4,0

3,75l / ha

B-C

133

5,3

MANKAR HQ 30

MANKAR HQ 45

at a walking speed of 4 km/h and 20 °C Roudup PowerFlex at a walking speed of 4 km/h and 20 °C Roudup PowerFlex

applied

Pre-position Droplets per

ml per

applied

Pre-position

Droplets per

ml per

quantity desired metering knob

minute

minute

quantity desired metering knob

minute

minute

1l / ha

A

50

2,0

1l / ha

B

75

3,0

2l / ha

B

100

4,0

2l / ha

B-C

150

6,0

3l / ha

B-C

150

6,0

3l / ha

C

225

9,0

3,75 l / ha

C

200

8,0

3,75l / ha

C-D

300

12,0

Contens: - MANKAR HQ 
               - Reservoir 0,5L HQ 
               - Charger 6V 
               - Shoulder strap 
               - Stretch covers for spray 
                  hood     
               - Operating instructions

 

 Insert the resevoir into the guide 

rail and fix it with the knurled 

head screw 

MAKE SURE THAT YOU 

CHARGE THE MANKAR 

HQ 

Droplets/min

 

O.K.

 

Droplets/min

 

ml/min

 

Summary of Contents for HQ 30

Page 1: ...agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray a...

Page 2: ...scosity are suitable If you intend to use a product other than Roundup UltraMax its application should be initially tested on a trial basis over a small area In any case the usage instructions for the...

Page 3: ...PowerFlex applied Pre position Droplets per ml per applied Pre position Droplets per ml per quantity desired metering knob minute minute quantity desired metering knob minute minute 1l ha A 50 2 0 1l...

Page 4: ...sired volume can be regulated at the metering valve by setting a greater or lesser flow rate Spray width Hold the applicator in its working position above the overlay e g cardboard or paper Actuate th...

Page 5: ...charge The applicator can be used for ca 8 hours with a fully charged battery Battery and motor monitoring If the battery is fully charged the LED lights green If the battery was charged for 8 hours...

Page 6: ...width from 2007 without atomiser and spray hood bracket 102965 Screw kit MANKAR HQ 102445 Charger 100 240 6V DC 450mA NEW no pic Item Part No Description Item Part No Description 103150 Atomiser for M...

Page 7: ...le Tank cleaner and mount it 3 Set the Dosing valve to the max water tap symbol 4 Switch the unit on switch on hand grip let it run for app 3 minutes 5 Charge the MANKAR HQ with the attached charger 6...

Page 8: ...le responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR HQ with 0 5 l reservoir MANKAR HQ with 1 l bottle Hiske Wei...

Reviews: