–11
4–
UG065 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
*: peak fan motor shut down.
10
8.68-20.50*
11.23-14.60
6.37-8.40
21
13.50-12.66
1.88-1.40
11.25-14.65
6.40-8.51
32
19.04-17.06
2.43-1.85
11.33-16.65
6.53-10.02
43
25.01-22.24
3.15-2.65
13.34-19.87
8.02-12.20