–11
1–
UG050W SELF-CONTAINED WATER-COOLED
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
13.33-9.09
3.44-2.04
6.40-7.83
4.75-6.41
21
13.39-12.45
3.60-1.35
6.75-10.55
5.10-6.30
32
15.96-15.95
4.40-1.34
8.43-12.43
6.20-6.20
43
17.18-16.40
5.00-1.75
8.57-17.62
6.81-6.63