–93–
UG030A-261 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
5.11-4.37
0.32-0
4.74-10.91
1.10-2.01
21
7.78-5.61
0.64-0.20
5.50-11.30
1.28-2.38
32
10.40-7.51
0.88-0.24
7.08-13.98
1.79-3.20
43
14.92-13.89
1.35-0.655
9.73-17.59
2.35-4.10