Maintenance
Section 4
4-8
Part Number 80-1629-3
Water Level Probe
1. Remove the water trough.
2. The water level probe normally does not require
removal for cleaning. The probe can be wiped and
cleaned in place or proceed to step 3.
3. Pull the water level probe straight down to
disengage.
4. Lower the water level probe until the wiring
connector is visible. Disconnect the wire lead from
the water level probe.
5. Remove the water level probe from the ice machine.
Water Pump
1. Empty the water trough.
A. Move the toggle switch from OFF to ICE.
B. Wait 45 seconds.
C. Place toggle switch in OFF position.
Water Pump Removal
2. Remove the water trough.
3. The water pump normally does not require removal
for cleaning. The water pump base can be wiped
and cleaned in place or proceed to step 4.
4. Grasp pump and pull straight down on pump
assembly until water pump disengages and
electrical connector is visible.
5. Disconnect the electrical connector.
6. Remove the water pump assembly from ice
machine.
7. Do not soak the water pump in cleaner or sanitizer.
Wipe the pump and ice machine base clean.
!
Warning
Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.
SV3141
WATER LEVEL PROBE
!
Warning
Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply before proceeding.
SV3091
WATER
PUMP
WATER
PUMP BASE