Installation Instructions
Section 2
2-8
Part No. 80-1375-3
Q320/370/420 Ice Machines
Q280 - Q1000 Ice Machines
Ice Machine
Voltage
Phase
Cycle
Air-Cooled
Water Cooled
Maximum Fuse/
Circuit Breaker
Minimum
Circuit Amps
Maximum Fuse/
Circuit Breaker
Minimum
Circuit Amps
Q320
115/1/60
15
11.2
15
10.5
208-230/1/60
15
4.8
15
4.2
230/1/50
15
5.2
15
4.7
Q370
115/1/60
20
12.9
20
12.2
208-230/1/60
15
6.2
15
5.8
230/1/50
15
6.2
15
5.8
Q420
115/1/60
20
12.3
20
11.4
208-230/1/60
15
7.8
15
7.4
230/1/50
15
6.3
15
5.9
Ice Machine
Voltage
Phase
Cycle
Air-Cooled
Water Cooled
Remote
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
Q280
115/1/60
20
12.6
20
11.7
N/A
N/A
208-230/1/60
15
5.7
15
5.2
N/A
N/A
230/1/50
15
5.7
15
5.2
N/A
N/A
Q450
115/1/60
20
12.8
20
11.9
20
13.6
208-230/1/60
15
7.8
15
7.4
N/A
N/A
230/1/50
15
6.1
15
5.7
N/A
N/A
Q600
208-230/1/60
15
9.2
15
8.7
15
9.3
230/1/50
15
9.2
15
8.8
15
9.4
Q800
208-230/1/60
20
12.1
20
11.4
20
11.9
208-230/3/60
15
8.9
15
8.2
15
8.9
230/1/50
20
12.0
20
10.6
20
11.2
Q1000
208-230/1/60
20
14.3
20
13.2
20
14.2
208-230/3/60
15
9.8
15
8.8
15
9.9
230/1/50
20
15.6
20
14.2
20
14.6
Q1300
208-230/1/60
30
19.5
30
18.1
30
19.8
208-230/3/60
20
13.1
20
11.6
20
12.7
230/1/50
30
15.7
30
14.3
30
14.7
380-415/3/50
N/A
N/A
N/A
N/A
15
7.3
Q1600
208-230/1/60
N/A
N/A
30
17.2
30
18.2
208-230/3/60
N/A
N/A
20
11.0
20
12.0
230/1/50
N/A
N/A
N/A
N/A
N/A
N/A
380-415/3/50
N/A
N/A
N/A
N/A
N/A
N/A
Q1800
208-230/1/60
40
28.1
40
26.7
40
26.9
208-230/3/60
20
15.5
20
14.1
20
13.9
230/1/50
40
23.3
40
21.9
40
22.2
380-415/3/50
N/A
N/A
N/A
N/A
15
9.1