4-4
Maintenance
Section 4
E. Remove the Float Valve
•
Turn the splash shield counterclockwise one or
two turns.
Float Valve Removal
•
Pull the float valve forward and off the mounting
bracket.
•
Disconnect the water inlet tube from the float
valve at the compression fitting.
•
Remove the cap and filter screen for cleaning.
F. Remove the Water Trough
•
Apply downward pressure on the siphon tube and
remove from the bottom of the water trough.
•
Remove the upper thumbscrew.
•
While supporting the water trough remove the
two thumbscrews from beneath the water trough.
•
Remove the water trough from the bin area
SPLASH SHIELD
FLOAT
SHUT-OFF
VALVE
COMPRESSION
FITTING
FLOAT VALVE
BRACKET
SV1695-2
CAP AND FILTER
SCREEN
SV1689-1
UPPER
THUMBSCREW
REMOVE SIPHON
TUBE
LOWER
THUMBSCREWS