UDE080 OPERATING TEMPERATURES
70°F/21°C Water
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Line
Temp °F/°C
Suction
Line
Temp °F/°C
Discharge
Line
Temp °F/°C
Suction
Line
Temp °F/°C
50
10
155-175
68-79
68-58
20-14
160-175
71-79
50-60
10-16
70
21
160-185
71-85
70-50
21-10
160-190
71-85
50-65
10-18
80
27
170-200
77-93
75-58
24-14
170-200
77-94
55-70
13-21
90
32
180-205
82-96
85-65
29-18
185-210
85-99
55-75
13-24
100
38
190-220
88-104
88-70
31-21
200-220
93-104
60-75
16-24
90°F/32°C Water
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Line
Temp °F/°C
Suction
Line
Temp °F/°C
Discharge
Line
Temp °F/°C
Suction
Line
Temp °F/°C
50
10
155-180
68-82
75-50
24-10
160-185
71-85
52-65
11-18
70
21
160-185
71-85
75-53
24-12
165-190
74-88
52-65
11-18
80
27
170-195
77-91
80-58
27-14
175-195
79-91
57-75
14-24
90
32
190-205
88-96
85-64
29-18
195-215
90-102
55-75
13-24
100
38
190-215
88-102
91-70
33-21
195-220
91-104
60-80
16-27
Summary of Contents for NEO UD0140A
Page 2: ......
Page 20: ...20 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 182: ...182 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 252: ...252 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE065 1 2 3 4 5 6 ...
Page 254: ...254 Part Number 000014797 Rev02 05 18 ELECTRONIC CONTROL BOARD UDE080 1 2 3 4 5 6 7 8 9 10 ...
Page 258: ...258 Part Number 000014797 Rev02 05 18 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 259: ......