RATED CAPACITY LIMITER
7
Setting up the Hydraulic Filter Reminder
This display allows the operator to setup a reminder to
check/replace the hydraulic return and suction filter on the
crane. The operator can select one of three different
intervals. When the timer expires, an indicator is turned on
for the operator to know it is time to change the filter. To reset
the timer, select the far right icon. Table 7-8 shows available
options.
Setting RCL Screen Brightness
The brightness of the RCL screen can be changed. Adjust
the screen to one of a range of 15 settings.
1.
In the Tools menu, select the screen brightness
icon.
2.
Increase or decrease the brightness as necessary using
the directional arrow key.
About Adjusting Joystick Output
The crane is equipped with electronic joysticks which allow
for more customization from the operator. The maximum
speed of all crane functions can be decreased from 100%
(default value) to either 75%, 50%, or 30% using this feature.
If desired, each crane function can be set discretely to a
value less than the default value of 100%. For example, the
operator can set swing to be 50% and all other outputs to
75% if desired. When these settings are modified from all
functions at the default 100% setting, this setup icon is
shown on the top left corner of the operating mode screen
while the crane is being operated as a visual feedback to the
current or future operators that a joystick setting is set.
These values change in real-time and are saved at machine
shutdown. It is important to note that when a joystick setting
is set to less than 100%, full use of the crane joystick is still
allowed, but the maximum function speed is reduced
according to the speed reduction.
Select function key 2 Tools on the MAIN Menu screen and
the Tools menu appears.
Accessing the Joystick Output Setup Screen
•
Select the Joystick Output Setup icon
to display
the Joystick Output Setup screen.
Joystick Output Setup
About the Joystick Output Setup Screen
The Joystick Output Setup screen allows the operator to
select what percentage of maximum hydraulic valve spool
shift to use when operating the crane in “Crane Control.” This
function does NOT work in “Radio Remote Control”.
•
The top horizontal bar on the Joystick Output Setup
screen allows the operator to select all the crane
functions be set to either 100%, 75%, 50%, or 30%.
•
The five vertical bars on the screen allow the operator to
select a range of either 30%, 50%, 75%, or 100% for
each function. Each function is identified by the icon at
the top of the vertical bar as noted in the following table.
•
Yellow indicates the current setting.
•
Default value for the Joystick Output screen is all values
@ 100%, as shown in Joystick Output #2 screen.
Table 7-8 Hydraulic Filter Reminder Icons
Icon
Description
Configure
—Highlight and press OK
to change the interval of the hydraulic filter
reminder. The icon is shaded YELLOW when
enabled.
Set Interval
—Highlight and select the
interval using the directional control keys.
The interval can be set for 40, 250, or 500
hours.
Reset
—Highlight and press OK
to
reset the reminder. Reset restarts the timer at
the configured interval.
Table 7-9 Joystick Output Icons
Swing Control
Boom Telescoping
Auxiliary Hoist
Main Hoist
Boom Lift
8807-37
Fo
r
Reference
Only