VPC-MAX Beam Switch Adjustments
The VPC-MAX beam maximum tray in and maximum tray
out switches require adjustment.
Maximum Tray In Switch Adjustment
for the following.
Adjust the forward limit switch position so that it will trip the
limit switch when the counterweight tray reaches a position
that is 409 mm (16.1 in) away from the forward physical stop.
Maximum Tray Out Switch Adjustment
for the following.
Adjust the rear limit switch position so that it will trip the limit
switch when the counterweight tray reaches a position that is
466 mm (18.3 in) away from the rear physical stop and 6327
mm (249.1 in) away from the forward physical stop.
FIGURE 10-51