![Manitowoc MLC650 Service Maintenance Manual Download Page 245](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260245.webp)
Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
7-9
MLC650 SERVICE/MAINTENANCE MANUAL
POWER TRAIN
7
Changing the Filters
for the following procedure.
The air cleaner has one primary filter (1d) and one
secondary filter (1e).
1.
Unfasten the clamps (1b) and carefully remove the
service cover (1a).
2.
Carefully remove the primary filter. There will be some
initial resistance, similar to breaking the seal on a jar.
Gently move the end of the filter back and forth to break
the seal, while trying to avoid dislodging any dust from
the filter.
NOTE:
The secondary filter should be replaced every third
time the primary filter is replaced. Inspect the
secondary filter and replace as necessary.
3.
Remove the secondary filter by pulling on the plastic ring
tabs. Avoid dislodging any dust from the filter.
4.
Clean the sealing surfaces in the housing.
Use a clean cloth to wipe clean the sealing surfaces and
the inside of the housing.
5.
Clean the inside of the outlet tube.
Carefully wipe the inside of the outlet tube using a clean
cloth, while being careful not to damage the sealing area
of the tube.
6.
Visually inspect old filters for leaks. A streak of dust on
the clean side of a filter is a telltale sign. Remove any
cause of leaks before installing a new filter.
7.
Inspect the new filters, especially the sealing area.
Never install damaged filters.
8.
Install the new filters in a timely manner to shorten the
amount of time the opened air cleaner is exposed to the
environment.
9.
Carefully install the new secondary filter (if required) and
gently push it into the back of the housing. Evenly apply
pressure to make sure the filter is completely seated in
the housing.
10.
Repeat
for the primary filter.
11.
Install the service cover, making sure that the O-ring is in
place and that the filter lines up with its support feature
on the cover.
12.
Fasten the service cover using the clamps. The cover
should seat without extra force.
13.
Push the reset button (8b) on the service indicator (8).
CAUTION
Avoid Engine Damage!
Dust on the sealing surfaces could render the seal
ineffective and cause leakage. Ensure all contamination
is removed before installing the new air filters.
Dirt accidentally transferred to the inside of the outlet tube
will reach the engine and cause wear. It takes only a few
grams of dirt to destroy an engine.
CAUTION
Avoid Air Filter Damage!
Never use the clamps on the service cover to force the
filters into the air cleaner housing. Using the clamps to
push the filters in could damage the housing and will void
the warranty.
Summary of Contents for MLC650
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc MLC650 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 375: ...R e f e r e n c e O n l y ...
Page 376: ...R e f e r e n c e O n l y ...