11
Section 2
Installation
Location Requirements
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
•
The location must be free of airborne and other
contaminants.
•
The location must not be near heat-generating
equipment or in direct sunlight.
•
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
•
The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
•
The location must not obstruct airflow through or
around the ice machine.
•
The location must not allow exhaust fan heat and/or
grease to enter the condenser.
•
The location must allow electrical, water, drain and
refrigeration tubing to enter the ice machine from the
back.
•
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
These ice machines are intended for use in household
and similar applications such as:
•
Staff kitchen areas in shops, offices and other work
environments
•
Clients in hotels, motels, farmhouses, bed and
breakfast and other residential type environments
•
Catering and similar non-retail applications
MINIMUM/MAXIMUM TEMPERATURES
ICE MACHINE CLEARANCE REQUIREMENTS
CONDENSING UNIT CLEARANCE REQUIREMENTS
!
Warning
PERSONAL INJURY POTENTIAL
Remove all ice machine panels before lifting and
installing.
Model
Minimum Air
Temperature
Maximum Air
Temperature
All Ice Machine Head
Sections
35°F
2°C
110°F
43°C
ICVD0695 - ICVD0696
ICVD1195 - ICVD1196
ICVD2095 - ICVD2196
-20°F
-29°C
120°F
49°C
ICVD0895 - ICVD0896
ICVD0996
ICVD1095 - ICVD1096
ICVD1495 - ICVD1496
ICVD1895 - ICVD1896
-20°F
-29°C
130°F
54°C
Model
Top
Back
Sides
I0600C - I0686C
I0870C - I0876C
I0976C
I1070C - I1076C
I1176C
I1470C - I1476C
I1870C - I1876C
I2170C - I2176C
5"
13 cm
*3" - 5"
*8 - 13 cm
5"
13 cm
IB0690C
IB0890C - IB0896
IB1090C - IB1096
2"
5 cm
5"
13 cm
8"
20 cm
* Routing utilities out top - Routing utilities out back
24" (61 cm) is recommended on all sides for servicing
Model
Top/Sides
Back
Front
ICVD0695 - ICVD696
ICVD0895 - ICVD896
ICVD0996
ICVD1095 - ICVD1096
ICVD1195 - ICVD1196
ICVD1495 - ICVD1496
ICVD1895 - ICVD1896
ICVD2095 - ICVD2096
*0"
*0 cm
48"
122 cm
48"
122 cm
* 24" (61 cm) is recommended on top/sides for servicing
Summary of Contents for IB1096YC
Page 26: ...Installation Section 2 26 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...Operation Section 3 38 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 51: ...Section 5 Customer Support Part Number 000007924 5 14 51 ...
Page 55: ...Table des matières suite 50 Part Number 000007924 5 14 ...
Page 73: ...Installation Section 2 68 Part Number 000007924 5 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...Section 5 Service clientèle Part Number 000007924 5 14 93 ...