PREVENTATIVE MAINTENANCE
CD5515-2/YB5515-2 SERVICE MANUAL
5-24
Published 1-20-2017, Control# 483-02
7.
Install the new element over the opening in the housing
and slide it all the way in.
8.
Make sure the gasket is seating evenly. If you don’t feel
the gasket is seating evenly for a perfect seal, you won’t
have protection. Recheck to see if the sealing surface in
the housing is clean.
9.
Install the air cleaner housing cover.
10.
Reset the air cleaner restriction indicator by pushing in
the reset button (Figure 5-33).
Add Rust Inhibitor to Engine Cooling System
For maximum protection of the engine cooling system, add a
corrosive inhibitor to the radiator. When the engine is cold,
remove the radiator cap and pour the inhibitor in the radiator
reservoir, following manufacturer’s instructions.
Lubricate the Outrigger Slides
1.
Lower the outriggers.
2.
Clean the tops of the outriggers with a suitable solvent.
3.
Apply Mobil EP grease, or equivalent, to the areas
shown in Figure 5-34. Do not over lubricate. Raise and
lower the outriggers several times to spread the grease.
Add Grease to the Swing Gearbox
NOTE:
It is necessary to climb under the crane to add
grease to the swing gearbox. Be sure engine is
shut off, the ignition key is removed and chock
blocks are in place before climbing under the
crane.
The grease fitting for adding grease to the swing gearbox
can only be reached from under the crane. It will be
necessary to use a light to see the fitting.
FIGURE 5-33
Air Cleaner
Restriction
Indicator
Tier 3 Engine
Tier 4 Engine
Resetting the Indicator Button
Push to
Reset
Push to
Reset
FIGURE 5-34
Apply Lubricant
Reference Only