![Manitowoc Grove GRT8120 Operator'S Manual Download Page 315](http://html.mh-extra.com/html/manitowoc/grove-grt8120/grove-grt8120_operators-manual_701202315.webp)
Grove
Published 3-22-2021, Control # 702-02
5-7
GRT8120 OPERATOR MANUAL
SET-UP AND INSTALLATION
5
RCL Light Tower (Optional)
The RCL Light Tower (1, Figure 5-6) is an optional feature
located on the front right of the crane cab. It must be
retracted for transport and extended for operation.
Retracting the RCL Light Tower for Transport
1.
Remove retaining clip (2) and pin (3) from the mounting
bracket (4).
2.
Slide the RCL light tower down to the retracted position.
Align the retract position hole (5) in the tower post with
the hole in the mounting bracket.
3.
Install the pin (3) in the mounting bracket (4) and tower
post. Secure the pin with the retaining clip (2).
Extending the RCL Light Tower for Operation
1.
Remove the retaining clip (2) and pin (3) from the
mounting bracket (4).
2.
Slide the RCL light tower (1) up to the extended position.
Align the extend position hole (6) in the tower post with
the hole in the mounting bracket (4).
3.
Install the pin (3) in the mounting bracket (4) and tower
post. Secure the pin (3) with the retaining clip (2).
1
FIGURE 5-6
3
2
4
5
Working Position
Transport Position
6
9939
9940
9941
Summary of Contents for Grove GRT8120
Page 1: ...Operator Manual Grove GRT8120 ...
Page 4: ...THIS PAGE BLANK ...
Page 16: ...TABLE OF CONTENTS GRT8120 A 12 THIS PAGE BLANK ...
Page 24: ...INTRODUCTION GRT8120 OPERATOR MANUAL 1 8 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Page 440: ...GRT8120 OPERATOR MANUAL A 10 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Page 447: ......