1-22
1.12.3 MIB (Manual Interface Board) Pin Positions and Harnesses
Connector
From/To
Harness # Pin #
Function
Voltage
Wire Color
J1 Controller
J7
8074546
1 Ground
Black
2 CAN Lo
Red
3 CAN Hi
White
4
5
6
J2 AIF
J5
8074850
1 Ground
Black
2 CAN Lo
Red
3 CAN Hi
White
4 5VDC+
5VDC
Black
5 24VDC
24VDC
Red
6 Ground
White
J5
Transformer
8075800
Bulk
8075780
Non-Bulk
1 24VAC
24VAC
Black
2 24VAC
Ret
White
Filter Relay
3 Pump
Motor
24VDC
Red
4 Pump
Motor
Green
5
6
Bulk Open Switch
7 Open
Switch
+
Black
Bulk Closed Switch
8 Closed
Red
9
10
Pan Switch
11 Pan Sw +
24VDC
Black
12 Pan Sw -
Red
13
14
Bulk Open Switch
15 Ground
-
White
Bulk Closed Switch
16 Ground
-
Green
J6
To Bulk connection in
rear of fryer
8075789
1 From bulk oil transformer
24VAC
Black
2 Common Return
White
3
To bulk oil fresh oil pump
relay 24VAC
Green
4
5
6
7
8
From bulk oil "Waste Tank
Full Sensor" Test Pins 2 to
8
24VAC –
Full
0VAC –
Not Full
Red