Part Number: 000015431 Rev01 5/19
185
IT1200C/CVDT1200
Remote Air-Cooled Condensing Unit Model
Characteristics vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
6.4-7.7
7.4-8.8
7.8-9.4
.75-2.5
80/27
7.2-8.6
7.7-9.1
8.2-9.7
90/32
7.6-9.0
8.0-9.5
8.8-10.4
100/38
8.3-9.9
8.5-10.1
9.9-11.8
110/43
8.9-10.6
9.7-11.5
10.5-12.4
1
Times in minutes - Dice cube
24-Hour Ice Production
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10
70/21
90/32
-20 to 70/
-29 to 21
1075
1005
955
80/27
1025
975
925
90/32
985
940
870
100/38
910
890
780
110/43
860
800
745
1
Based on average ice slab weight of 6.2 - 7.2 lb.
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
230-340
70-40
155-200
110-135
70/21
275-350
70-40
160-210
110-130
80/27
290-360
70-41
170-210
115-140
90/32
310-370
75-41
180-210
120-140
100/38
365-470
90-44
220-315
130-175
110/43
375-480
90-45
225-320
150-175
Summary of Contents for CVDF0600
Page 1: ...Part Number 000015431 Rev01 5 19 QuietQube Series Ice Machines Technician s Handbook ...
Page 2: ......
Page 12: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 68: ...68 Part Number 000015431 Rev01 5 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 210: ...210 Part Number 000015431 Rev01 5 19 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 211: ......