background image

 

C, E, & H-0200 COMPRESSOR REPLACEMENT ASSEMBLIES 

                                                                                                                                        Installation Instructions 

 

Item

 

Qty.

 

 

Description

 

 

   

 

   

P/N

 

   1 

Compressor Adapter Plate 

 

 

6635214 

   2 

Component Mounting Bracket 

 

 

6264614 

      3 

#10-24 x 1/2 Thread Cutting Screw  

 

5202093 

      4 

#8 Flat Head Sheet Metal Screw 

 

 

5025553 

   5 

Lead Wires        

 

 

2075623, 2075633, 2075643, 2075653, 2075663, 2075673 

   6 

Installation Instructions 

 

 

8002233 

   7 

Wire Shield 

 

 

6278414 

   8 

#10-24 Hex Nuts 

 

 

5429291 

   9 

#10 Lockwashers 

 

 

5573163 

  10 

Extruded  Tape 7 1/4” Long 

 

 

9202483 

 

ON C, E, & H-0200 SERIES ICE MACHINES 

To replace a Tecumseh compressor with a B/M number of AK159AT-032-H4, AK159ET-032-H4, or AK163JT-032-C4, items 1 
through 5 are not required.    All components are directly replaceable. 
 
To replace a Tecumseh compressor with a B/M number of AE256AT-681-A4, AE334JT-616-A4, or AE255ET-616-A4, all the items 
are required.    Follow the instructions below: 

1.

 

After the old compressor has been removed, fasten down the compressor adapter plate to the ice machine base.  Locate by 
using the four weldstuds, lockwashers, and hexnuts from the old compressor mounting. 

2.

 

Mount the new start capacitor and start relay to the component mounting bracket, as shown.  Mount this component and 
bracket assembly on the adapter plate.    Locate over the two outside weldstuds, with the components facing out, as shown. 

3.

 

Install the new compressor with existing sleeves, grommets, lockwashers, and hexnuts.  Note:  The compressor should be 
located so that the electrical hookup box is facing the inside of the ice machine. 

4.

 

New compressor refrigeration ports are not located in the same position as the original compressor refrigeration ports.  
Repiping will be required. 

5.

 

Using supplied wires, wire the: 

compressor protector “3” to toggle switch “17” 
start relay “L” to transformer board “19” 
start relay “M” to compressor “R” 
start capacitor to compressor “S” 
start relay “S” to start capacitor 

6.

 

Important:    Change the numerical marking for the compressor protector on the existing wiring diagram (on front panel label) 
to correspond with the new compressor (change the 3 to a 1 and the 1 to a 3). 

7.

 

On 50 Hz., 230V machines, remove the crankcase pressure regulator valve (CPR valve). 

8.

 

Apply wire shield (see illustration on bottom of page) to existing protruding screws of the ice machine base.    Apply tape, as 
shown on illustration. 

 
 
 
 
 
 
 
 
 
 
 
 

Manitowoc Ice, Inc.                                                                                                                                                                     

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI  54221-1720 USA                                                                              
Telephone 920-682-0161, Fax - Sales:    920-683-7589, Service/Parts: 920-683-7585,    Other:  920-683-7879                              8002233 
Web Site - 

www.manitowocice.com

                                                                                                                                                                                                      Rev. 03/30/99 

Reviews: