2-12 

Determine Type Of Solution Needed 

 

 

CAUTION

 

Use only Manitowoc-approved Ice Machine 
Cleaner (part number 94-0546-3) or Sanitizer (part 
94-0565-3) in the AuCS

®

A It is a violation of 

Federal law to use these solutions in a manner 
inconsistent with their labeling. Read and 
understand all labels on the bottles before use. 

 

The AuCS

®

A accessory will dispense Cleaner OR 

Sanitizer. It cannot dispense both at the same time. 

 

 

CAUTION

 

Do not mix Cleaner and Sanitizer solutions 
together. It is a violation of Federal law to use these 
products in a manner inconsistent with their 
labeling. 

 

MANITOWOC ICE MACHINE CLEANER 
Part Number 94-0546-3 

Ice Machine Cleaner is used to control build-up and 
to remove lime scale or other mineral deposits. It will 
not “sanitize” the ice machine. 

It is recommended for use in places that have lime 
scale or other mineral deposits built up, but no 
problems with slime. 

MANITOWOC ICE MACHINE SANITIZER 
Part Number 94-0565-3

 

Ice Machine Sanitizer is used for sanitizing and 
controlling algae build-up (slime) and other bacterial 
growth. The ice machine should be sanitized on a 
regular schedule, following Manitowoc 
recommendations and local regulations. 

It is recommended for use in places such as pizzerias, 
bars, bakeries, etc., that have airborne bacteria 
(yeast). Sanitizing is also recommended in places that 
do not have lime scale (or other mineral deposit 
problems). 

Model 

Amount of Cleaner or 

Sanitizer Dispensed 

Q200  Q280  Q320  Q370  Q420 

Q450  Q600  Q600C  IB600C  

Q800  Q800C  IB800C  Q1000 

Q1000C  IB1000C  SU1000C  

Q1400C  

 

*2.4 ounces (70 ml) 

Q1300  Q1600  Q1800  QDUAL  *4.8 ounces (140 ml) 

*The dispense rate is automatically controlled 

Installing Bottle Of Solution 

 

 

WARNING

 

Wear rubber gloves and safety goggles (and/or face 
shield) when handling Cleaner or Sanitizer. 

 

 

 

CAUTION

 

Follow instructions listed under “Changing 
Solution Type” on the next page when changing 
from Cleaner to Sanitizer or from Sanitizer to 
Cleaner. 

 

1.  Place the bottle into the AuCS

®

A accessory. 

2.  Slide the tube to the bottom of the bottle and 

hand-tighten the cap. 

 

 

TUBE MUST BE CLOSE 

TO BOTTLE BOTTOM 

SV1645

 

Bottle Installation 

 

 

WARNING

 

Do not use 1 gallon bottles of Cleaner or Sanitizer 
on the AuCS

®

Summary of Contents for AUCS Q

Page 1: ...llation Use and Care Manual This Manual Covers Installation Use and Care Information for the AuCS A Accessory We reserve the right to make product improvements at any time Specifications and design ar...

Page 2: ...fully Procedural Notices When installing or using the Model AuCS A accessory be sure to read the procedural notices in this manual These notices supply helpful and important information Throughout thi...

Page 3: ...Installation Instructions General 2 1 Electrical Service 2 1 Location Mounting 2 2 Connection to Ice Machine 2 4 Determine Type of Solution Needed 2 12 Installing Bottle of Solution 2 12 Changing Sol...

Page 4: ...Table of Contents ii THIS PAGE INTENTIONALLY LEFT BLANK...

Page 5: ...days of delivery Do not attempt to repair the damage 4 Concealed Damage A If damage is noticed at the time of installation notify the distributor immediately and ask for an inspection B Do not destro...

Page 6: ...s outlined in this manual 2 Repairs due to unauthorized modifications to the ice machine or the AuCS A accessory or the use of non standard parts without prior written approval from Manitowoc Ice Inc...

Page 7: ...E BACK OF THE CONTROL BOX CLEANING FREQUENCY SELECTOR SWITCH ELECTRIC CORD TO DISPENSING PUMP CONTROL BOARD ELECTRIC CORD FOR POWER TO AuCS COMMUNICATION CONNECTION COMMUNICATION WIRE IS SUPPLIED WITH...

Page 8: ...compatible Listed models are compatible with the AuCS A accessory Q MODELS Air Water or Remote Condenser J MODELS Air Water or Remote Condenser B MODELS Air Water or Remote Condenser B150 Q200 J200 B2...

Page 9: ...local state and national codes Voltage Cycle Phase Runnin g Amps N E M A Electrical Plug Configuration 115 60 1 3 5 15P 220 240 50 1 1 No plug attached 115 VOLT WIRING The 115 60 1 AuCS has an eight 8...

Page 10: ...ot dispense FASTENING TO BIN OR DISPENSER CAUTION The AuCS A accessory may be mounted to the bin or dispenser only when permitted by local electrical codes NOTE The ice machine s serviceability may be...

Page 11: ...SE OF ICE MACHINE Height and Distance Requirements SV1639G NO TOO HIGH 2 5 CM 2 5 CM BOX BASE OR BOX TOP MUST BE WITHIN 2 5 CM OF ICE MACHINE BASE NO TOO LOW NOTE BOX MUST ALSO MOUNT WITHIN REACH OF 9...

Page 12: ...t the PVC fitting A into the AuCS A and tighten with the lock nut C WARNING Disconnect the electric power supply to the ice machine at the electrical disconnect before proceeding FOAM TAPE E 2 If requ...

Page 13: ...ne cont Q200 Q280 Q450 Q600 Q800 Q1000 Q1300 Q1600 Q1800 Q320 Q370 Q420 Q600C Q800C Q1000C 1 1 8 DIAMETER ACCESS HOLE PVC Conduit Fitting A Installation SV1637G 5 3 1 5 1 5 LOCKNUT C PVC CONDUIT FITTI...

Page 14: ...Installation Instructions Section 2 2 6 IB600C IB800C IB1000C Q1400C 1 1 8 DIAMETER ACCESS HOLE 1 1 8 DIAMETER ACCESS HOLE 5 9 7 5 2 3 0 QDUAL 1 1 8 DIAMETER ACCESS HOLE 7 5 2...

Page 15: ...VC conduit from the AuCS A to the ice machine CAUTION Install 1 2 conduit to protect the tubing and modular wire from damage or access NOTE A pulling elbow is recommended for easier routing of the vin...

Page 16: ...INLET VALVE ACCESS HOLE SV1641G WATER INLET BARBED FITTING WATER INLET BARBED FITTING Vinyl Tubing Installation Typical 22 Ice Machine Shown SV3064 IB600C IB800C IB1000C ROUTE TUBING ROUTE TUBING AND...

Page 17: ...tubing part A B Connect the 1 4 ferrule nut with 1 4 tubing to the 90 threaded elbow part C and hand tighten C Locate the 7 16 diameter hole in the bulkhead of the ice machine See illustration D Remov...

Page 18: ...machine Plug into the jacks on the ice machine control board and the AuCS A control board Refer to drawing for routing communication wire in ice machine CONTROL BOARD COMMUNICATION WIRE GROUND WIRE Q...

Page 19: ...ing and into the water compartment 4 Determine the amount of tubing required and cut off the excess 5 Slide the 3 8 hose clamp Part B onto the tubing and connect it to the water inlet barbed fitting A...

Page 20: ...used for sanitizing and controlling algae build up slime and other bacterial growth The ice machine should be sanitized on a regular schedule following Manitowoc recommendations and local regulations...

Page 21: ...a new bottle of either Cleaner or Sanitizer solution Refer to Installing Bottle of Solution on previous page Hose Priming The dispenser pump requires priming only upon initial installation or if the...

Page 22: ...ons 4 9 are inoperative Do not use them Important Using the AuCS A accessory is supplemental to regular cleaning and sanitizing per Manitowoc recommendations and local regulations Removal From Service...

Page 23: ...ition and allow the ice to melt off the evaporator CAUTION Never use anything to force ice from the evaporator Damage may result Step 2 To start the automatic cleaning system move the toggle switch to...

Page 24: ...ts and the ice machine awaits a change in the toggle switch position Q1400C If the toggle switch is moved to OFF prior to the pump dispensing less than 45 seconds into the cycle then switched to ICE A...