Reference
Only
MAINTENANCE
2250 MAX-ER 2000 OPERATOR’S MANUAL
6-6
Published 01-08-13, Control # 049-05
FIGURE 6-7
A1162
View A
At Left Side
Mast Hinge Pin
CAUTION
Before adjusting limit switch, move limit switch up or down
in slots so edge of roller is even with edge of actuator
bracket. Roller must be fully extended. Limit switch will not
trip open if positioned too low in slots. Limit switch could
be damaged from over-travel if positioned too high in slots.
View B
View C
Protractor-
Level
80° MAX
Angle
Mast Butt
Actuator
Bracket
Mast Butt
C
L
Limit
Switch
Electric Cord to
Junction Box
Equal
Distance
Rise in actuator bracket depresses limit switch
roller as mast angle reaches 80°. Depressed
roller opens normally closed limit switch to stop
mast hoist and apply drum brake.
Hinge Pin
Bolt
Bracket
Capscrews