background image

 
 

42 

 

2

nd

 Set Complete 

 

 

Minimum Length 

 

 

Minimum Length Begin 

 

 

Decimal Value 

See Appendix A

 

 

Minimum Length Complete 

 

4.15

 

  Industrial 2 of 5 Parameters 

4.15.1

 

Reading Type 

 

IATA25 Enable  

 

 

<IATA25 Disable> 

 

4.15.2

 

Check Digit Transmission 

 

<Do Not Calculate Check Digit> 

 

 

Calculate Check Digit and Transmit  

 

Summary of Contents for SG300BT

Page 1: ...U s e r s M a n u a l SG300BT Wireless Handheld Linear Imager Bar code Scanner ...

Page 2: ...nstallation 6 3 3 SG300BT Setup Bluetooth Communication 7 3 3 1 Pairing 7 3 3 2 Setup SPP Master Mode Communication 7 3 3 3 Setup SPP Slave Mode Communication 9 3 3 4 Setup HID Slave Mode Communication 9 3 3 5 Sleep Mode 9 3 3 6 Batch Mode 10 3 3 7 Out of Range 10 CHAPTER 4 CONFIGURING THE SG300BT 11 4 1 Preface 11 4 1 1 Changing Scanner Settings with Programming Codes 11 4 1 2 Programming Flow Ch...

Page 3: ...nner Pincode Mode 錯誤 錯誤 錯誤 錯誤 尚未定義書籤 尚未定義書籤 尚未定義書籤 尚未定義書籤 4 5 7 Scanner Pincode Setup 錯誤 錯誤 錯誤 錯誤 尚未定義書籤 尚未定義書籤 尚未定義書籤 尚未定義書籤 4 6 Bluetooth Cradle Setup 錯誤 錯誤 錯誤 錯誤 尚未定義書籤 尚未定義書籤 尚未定義書籤 尚未定義書籤 4 6 1 Cradle Pincode Mode 錯誤 錯誤 錯誤 錯誤 尚未定義書籤 尚未定義書籤 尚未定義書籤 尚未定義書籤 4 6 2 Cradle Pincode Setup 錯誤 錯誤 錯誤 錯誤 尚未定義書籤 尚未定義書籤 尚未定義書籤 尚未定義書籤 4 7 Scanner Operation 17 4 7 1 Reading Mode 17 4 7 2 Beeper Option 17 4 7 ...

Page 4: ...racters 27 4 10 1 Select Terminator 27 4 11 Code Type 28 4 11 1 Barcode Selection 28 4 12 UPC EAN JAN Parameters 31 4 12 1 Reading Type 31 4 12 2 Supplemental Setup 33 4 12 3 Check Digit Transmission 33 4 13 Code 39 Parameters 34 4 13 1 Type of Code 34 4 13 2 Check Digit Transmission 34 4 13 3 Output Start Stop Character 35 4 13 4 Decode Asterisk 35 4 13 5 Setup Code Length 35 4 14 Code 128 Parame...

Page 5: ...44 4 17 1 Check Digit Transmission 44 4 17 2 Setup Code Length 45 4 18 CODABAR NW7 Parameters 46 4 18 1 Setup Start Stop Characters upon Transmission 46 4 18 2 Transmission Type of Start Stop 46 4 18 3 Setup Code Length 47 4 19 Code 93 Parameters 49 4 19 1 Check Digit Transmission 49 4 19 2 Setup Code Length 49 4 20 Code 11 Parameters 51 4 20 1 Check Digit Transmission 51 4 20 2 Setup Code Length ...

Page 6: ...Databar Expanded Parameters 59 4 25 1 Symbology ID 59 CHAPTER 5 MISCELLANEOUS PARAMETERS 60 5 1 Bar Code ID 60 5 1 1 Default Barcode ID 60 5 1 2 User Define Code ID 61 5 2 Preamble and Postamble Insertion 63 5 2 1 Setup Insertion 63 5 2 2 Insertion Set Number 64 5 2 3 Code Type for Insertion 65 5 2 4 Position to Be Inserted 67 5 2 5 Characters to Be Inserted 67 5 3 Character Deletion 67 5 3 1 Dele...

Page 7: ...ES 72 A Decimal Value Table 72 B ASCII Value Table 73 C ASCII Table 74 D Function Key Table 80 E Technical Specifications 81 F Scan Map 83 G LED Indicator Status 84 H Test Symbologies 85 Quick Configuration 87 ...

Page 8: ...e SG300BT which supports the reading depth up to 50 centimeters and the scan speed is up to 500 scans per second In short SG300BT is absolutely a high performance gun type scanner which provides the customer with the most cost effective solution in the market It is perfectly suitable and definitely the best choice for any retailers using POS environment The SG300BT is available in various interfac...

Page 9: ...pment 8 For safety please tie wire well and don t put anything on the wire 9 If you don t use this equipment for long time please cut off the power to avoid damage from surge power 10 Don t spray any liquid on this scanner because it may cause a fire or short circuit 11 Please do not open the equipment For safety only the qualified serviceman can open the equipment 12 If there are the following si...

Page 10: ... the conditions below a The equipment will not cause any severe interference b The equipment can avoid any interference from environment Statement This product is classified as B class product In environment this product may cause some interference In this situation the user may do something to avoid interference ...

Page 11: ...ly press the red trigger button and aim the beam to the bar code It needs to position the beam to fall across all bars in the 1D barcodes You will hear one beep and the green LED indicator will light on after scan successfully The programming of the SG300BT is very easy You can setup the SG300BT by scan all necessary programming codes that meet applications Thanks to the powerful decoding software...

Page 12: ...s ordered Shipment Package a SG300BT Linear Barcode Scanner b Bluetooth Cradle c Communication Cable RS 232 keyboard wedge or USB d Power Adaptor e Product Compact Disc 4 Visually inspect the SG300BT and accessories for any evidence of physical damage 5 If anything is missing or appears to be damaged immediately contact your dealer ATTENTION Store the packing material and boxes it should be used w...

Page 13: ...the supplied communication cable at the bottom side of the cradle 2 Connect the other side of the communication cable to the right connector of your POS or HOST system 3 Plug the external power supply into the power jack on the bottom of the cradle 4 Plug the power supply into the AC outlet 5 Turn on your POS or HOST system ...

Page 14: ...etup the communication between the SG300BT scanner and the cradle follow the steps 1 The SG300BT scanner must scan SPP Master Mode barcode to set the SG300BT scanner in Master mode 2 Scan the Bluetooth MAC address code located on the bottom of the cradle 3 When the Bluetooth MAC was successfully scanned scanner will initiate with 3 short beep sounds Blue LED will blink followed by a long beep soun...

Page 15: ...he SG300BT is too low the SG300BT will indicate red LED and beeper warning It is important to know that the SG300BT scanner will only communicate with the cradle whose unique Bluetooth MAC address was last scanned If a cradle is paired with the SG300BT scanner another SG300BT scanner can t be paired with that cradle until the original connection is interrupted If you pair a second SG300BT scanner ...

Page 16: ...and Bluetooth HID profile application device follow the steps 1 The SG300BT scanner must scan HID Slave Mode barcode to set the SG300BT scanner in HID Slave mode 2 When control the Bluetooth device to search the scanner enter pin code to setup pair You can scan number barcode on Appendix B ASCII VALUE TABLE number 0 9 to setup 3 When SG300BT scanner is successful connected scanner Blue LED will al...

Page 17: ...ansmitted to the host When scan barcode Batch Data Clear all stored scanned data will be erased from memory The capacity of this memory depends on the scanned data The memory size is approximately 30 000 sets of EAN13 bar code type 3 3 7 Out of Range When Out of Range function is enabled and the scanner is working at out of transmission range the scanned data will be stored to out of range memory ...

Page 18: ...e sequence below 1 Power up the scanner 2 Open the scanner programming mode by scanning Start Configuration 3 Change scanner settings by scanning any of the programming code that meet applications 4 Close the scanner programming mode by scanning End Configuration 5 Save configuration by scanning Save Parameters An Example For changing the Baud rate to 38400 the following codes must be scanned succ...

Page 19: ...back to the factory default settings 4 1 2 Programming Flow Chart Start Configuration Recall Parameters Set all Default Interface Selection Communication Parameters Bar codes Parameters Misc Parameters etc End Configuration Abort Configuration Save Parameters ...

Page 20: ...ading a valid programming code the scanner will give a three high beep and the Green LED indicator will light on Set all the parameters to the factory default settings 4 3 General Process 1 Power up the Scanner 2 Scan the Start Configuration bar code 3 Scan the bar code for the desired feature 4 Scan End of Configuration bar code 5 Scan Save Parameters bar code ...

Page 21: ... by the parameters saved last time 4 3 3 Version Information Display the Scanner version information and date code Display the Cradle version information and date code Display the Scanner Bluetooth MAC Address Display the Cradle Bluetooth MAC Address 4 4 CRADLE Interface Selection 4 4 1 Interface Keyboard Mode ...

Page 22: ...nner Setup 4 5 1 Preface How to configure the Bluetooth function The barcode programming feature gives the possibility to change the SG300BT scanner settings with programming labels 4 5 2 Scanner Mode BT Parameter set default SPP Master Mode SPP Slave Mode HID Slave Mode ...

Page 23: ...an be executed directly by scanning barcode instead of doing the general process Batch Mode ON Batch Mode OFF Batch Data Output Batch Data Clear Delete Last Data 4 5 4 Out of Range Out of Range Enable Out of Range Disable 4 5 5 Sleep Mode Sleep Mode On 1 minute ...

Page 24: ...17 Sleep Mode On 10 minute Sleep Mode OFF 4 6 Scanner Operation 4 6 1 Reading Mode Good Read OFF Trigger ON OFF Continuous Trigger OFF Flash Auto Sence 4 6 2 Beeper Option High Medium ...

Page 25: ... scan Require 2 consecutive decoding of the same bar code data for a good scan Require 3 consecutive decoding of the same bar code data for a good scan Require 4 consecutive decoding of the same bar code data for a good scan 4 6 5 Sensitivity of Continuous Reading This feature is working under Reading Continuous Mode ...

Page 26: ...n 100ms interval Default value is 3 0 3 second To setup same code Delay reading interval 1 Scan the Begin label 2 Go the Decimal Value Tables in Appendix B Scan label s that represents the same code delay reading interval They are ranged from 1 50 One step is represented 0 1 second So the interval is from 0 1 to 5 seconds 3 Scan the Complete label Repeat the steps 1 3 to set time out of same symbo...

Page 27: ...20 4 6 7 Reverse Output Characters Example 012345 543210 Enable Disable 4 7 RS232 Mode Parameters 4 7 1 Baud Rate 1200 2400 4800 9600 19200 38400 57600 ...

Page 28: ...its 4 7 3 Parity A Parity bit is an extra data bit used to check data transmission errors None Even Select to set the parity bit either 1 or 0 to ensure the number of 1 Odd Select to set the parity bit either a 1 or 0 to ensure the number of 1 Mark Select to set the parity bit always 1 Space Select to set the parity bit always 0 ...

Page 29: ...wait for host to send an ACK or a NAK response If ACK is received then complete the data transmission If NAK is received re send the last set of data and wait for ACK NAK again ACK NAK OFF XON XOFF ON After transmitting data wait for host to send an XON or a XOFF response If XON is received then complete the data transmission If XOFF is received stop the transmission XON XOFF OFF ...

Page 30: ...d Wedge Mode Parameters 4 8 1 Terminal Type IBM PC AT PS 2 Includes IBM PS 2 and compatible models 50 55 60 80 IBM PC XT IBM PS 2 25 30 IBM 5550 IBM 102 Key IBM 122 Key 1 IBM 122 Key 2 NEC 9800 Apple Desktop Bus ADB ...

Page 31: ...24 4 8 2 Country Language US English UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese Belgium ...

Page 32: ...tuguese Denmark Netherlands Turkey 4 8 3 Upper Lower Case No Change Enable Lower Case Transmit all data as lower case Enable Upper Case Transmit all data as upper case 4 8 4 Capslock Detection Enable Disable ...

Page 33: ...26 4 8 5 Character by ALT Method ALT Method Enable Send ALT Method Disable 4 8 6 Select Numerical Pad Numerical Pad ON Numerical Pad OFF 4 8 7 Interscan Code Delay No Delay 5 ms 10 ms 25 ms 50 ms ...

Page 34: ...elect Terminator CR LF The scanner transmits a carriage return and a line feed after each scan CR Suffix The scanner transmits a carriage return after each scan LF Suffix The scanner transmits a line feed after each scan Space Tab STX ETX RS232 only None ...

Page 35: ...uld read all types of bar code If Disable is selected for a certain bar code type the scanner could not read the particular bar code The symbol of means default setting All Bar Codes ON UPC A ON UPC A OFF UPC E ON UPC E OFF EAN 13 JAN 13 ON EAN 13 JAN 13 OFF EAN 8 JAN 8 ON EAN 8 JAN 8 OFF ...

Page 36: ... ON CODE 39 OFF Code32 Italian Pharmacy ON Code32 Italian Pharmacy OFF Code 128 ON Code 128 OFF Interleave 2 of 5 ON Interleave 2 of 5 OFF Codabar NW7 ON Codabar NW7 OFF Industrial 2 of 5 ON Industrial 2 of 5 OFF ...

Page 37: ...30 Matrix 2 of 5 ON Matrix 2 of 5 OFF CODE 93 ON CODE 93 OFF CODE 11 ON CODE 11 OFF MSI PLESSEY ON MSI PLESSEY OFF Telepen ON Telepen OFF China Postage ON China Postage OFF ...

Page 38: ...ectional OFF GS1 DataBar Expanded ON GS1 DataBar Expanded OFF GS1 DataBar Limited ON GS1 DataBar Limited OFF 4 11 UPC EAN JAN Parameters 4 11 1 Reading Type UPC A EAN 13 ON Add 0 before UPC A to make it 13 digits UPC A EAN 13 OFF ISBN Enable ISBN Disable ...

Page 39: ...32 ISSN Enable ISSN Disable Decode with Supplement Auto Discriminate Supplement Expand UPC E Enable Expand UPC E Disable EAN8 EAN13 Enable EAN8 EAN13 Disable GTIN Format Enable GTIN Format Disable ...

Page 40: ...upplemental 2 5 Digit Supplemental 4 11 3 Check Digit Transmission UPC A Check Digit Transmission ON UPC A Check Digit Transmission OFF UPC E Check Digit Transmission ON UPC E Check Digit Transmission OFF EAN 8 Check Digit Transmission ON EAN 8 Check Digit Transmission OFF ...

Page 41: ...n OFF ISSN Check Digit Transmission ON ISSN Check Digit Transmission OFF 4 12 Code 39 Parameters 4 12 1 Type of Code Standard Code 39 Full ASCII Code 39 Italian Pharmacy Code 32 Off Italian Pharmacy Code 32 ON 4 12 2 Check Digit Transmission Do Not Calculate Check Digit ...

Page 42: ...sk Enable Disable 4 12 5 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional code length ...

Page 43: ...ariable Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin ...

Page 44: ...ix A Minimum Length Complete 4 13 Code 128 Parameters 4 13 1 Reading Type UCC EAN 128 Enable UCC EAN 128 Disable Enable C1 Code Format Disable C1 Code Format Enable Code128 Group Separators GS Disable Code128 Group Separators GS ...

Page 45: ...nd FNC2 ON OFF 4 13 4 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable ...

Page 46: ...t Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete ...

Page 47: ...rameters 4 14 1 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit 4 14 2 Setup Number of Character Even Odd 4 14 3 Brazilian Banking Code Enable Disable ...

Page 48: ... Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A ...

Page 49: ...Length Begin Decimal Value See Appendix A Minimum Length Complete 4 15 Industrial 2 of 5 Parameters 4 15 1 Reading Type IATA25 Enable IATA25 Disable 4 15 2 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit ...

Page 50: ...he desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin ...

Page 51: ...inimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4 16 Matrix 2 of 5 Parameters 4 16 1 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit ...

Page 52: ... Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A ...

Page 53: ...ngth Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4 17 CODABAR NW7 Parameters 4 17 1 Setup Start Stop Characters upon Transmission ON OFF 4 17 2 Transmission Type of Start Stop A B C D Start A B C D Stop ...

Page 54: ... the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length ...

Page 55: ...ariable Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin ...

Page 56: ... Not Transmit 4 18 2 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable Fixed Length 1st Set ...

Page 57: ...n Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete ...

Page 58: ... and Transmit Calculate Check 2 Digit and Not Transmit 4 19 2 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable ...

Page 59: ...t Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete ...

Page 60: ... 4 20 2 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length Variable Fixed Length 1st Set 1st Set Begin ...

Page 61: ...al Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete ...

Page 62: ...nsmit Calculate Check Digit and Not Transmit 4 21 3 Setup Code Length To set the fixed length 2 sets available 1 Scan the Begin programming code of the desired set 2 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the length to be read 3 Scan the Complete programming code of the desired set Repeat the steps 1 3 to set additional length ...

Page 63: ...et 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete ...

Page 64: ...eck Digit and Transmit Calculate Check Digit and Not Transmit 4 22 2 Application ID Transmit Application ID Add 01 before GS1 Databar Omnidirectional Do Not Transmit Application ID 4 22 3 Symbology ID Transmit Symbology ID Add e0 before GS1 Databar Omnidirectional Do Not Transmit Symbology ID ...

Page 65: ...te Check Digit and Transmit Calculate Check Digit and Not Transmit 4 23 2 Application ID Transmit Application ID Add 01 before GS1 Databar Limited Don t Transmit Application ID 4 23 3 Symbology ID Transmit Symbology ID Add e0 before GS1 Databar Limited Don t Transmit Symbology ID ...

Page 66: ...59 4 24 GS1 Databar Expanded Parameters 4 24 1 Symbology ID Transmit Symbology ID Add e0 before GS1 Databar Expanded Don t Transmit Symbology ID ...

Page 67: ...scanning code User may refer to the following table to know what kind of barcode has being scanned Code Type ID Code Type ID UPC A A UPC E B EAN 8 C EAN 13 D Code 39 E Code 128 F Interleave 2 of 5 G Industrial 2 of 5 H Matrix 2 of 5 I Codabar NW7 J Code 93 K Code 11 L China Postage M MSI Plessey N Telepen T GS1 DataBar Omni U GS1 DataBar Lim V GS1 DataBar Exp W ...

Page 68: ...the symbologies programming code 2 Go to the ASCII Table in Appendix B Scan programming codes that represent the desired ID Note User define code ID will override default value Program will not check the conflict It is possible to have more than two symbologies which have same code ID UPC A UPC E EAN 13 JAN 13 EAN 8 JAN 8 CODE 39 ...

Page 69: ...62 CODE 128 Codabar NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI PLESSEY Telepen GS1 DataBar Omnidirectional ...

Page 70: ...ndix A Scan programming codes that represent the desired position to be inserted 1 the first digit 99 the last digit 4 Scan the Complete programming code of Character Position to Be Inserted 5 Go to the ASCII Table in Appendix C Scan programming codes that represent the desired characters to be inserted 6 Scan the Complete programming code of Characters to Be Inserted Repeat the steps 1 6 to set a...

Page 71: ...64 Code UPC A 1st Digit Complete Complete End Configuration Save Parameters 5 2 2 Insertion Set Number 1st Set 2nd Set 3rd Set 4th Set ...

Page 72: ...65 5th Set 6th Set 5 2 3 Code Type for Insertion UPC A UPC E EAN 13 JAN 13 EAN 8 JAN 8 CODE 39 CODE 128 Codabar NW7 Interleave 2 of 5 ...

Page 73: ...66 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI PLESSEY Telepen GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes ...

Page 74: ...esired set 2 Scan the programming code of the desired symbology 3 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the desired position to be deleted 4 Scan the Complete programming code of Character Position to Be Deleted 5 Go to the Decimal Value Table in Appendix A Scan programming codes that represent the number of characters to be deleted 6 Scan the Complete p...

Page 75: ...s 1 6 to set additional deletion Example Delete first 3 digits Code EAN 13 Start Configuration 1st Set Code EAN 13 1st Digit Delete from the 1st digit Complete 3 Delete 3 digits Complete End Configuration Save Parameters ...

Page 76: ...69 5 3 1 Deletion Set Number 1st Set 2nd Set 3rd Set 4th Set 5th Set 6th Set 5 3 2 Code Type for Deletion UPC A UPC E EAN 13 JAN 13 EAN 8 JAN 8 ...

Page 77: ...70 CODE 39 CODE 128 Codabar NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI PLESSEY Telepen ...

Page 78: ...Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes None 5 3 3 Position to Be Deleted Decimal Value See Appendix A Complete 5 3 4 Number of Characters to Be Deleted Decimal Value See Appendix A Complete ...

Page 79: ...72 APPENDIXES A Decimal Value Table ...

Page 80: ...73 B ASCII Value Table 0 1 2 3 4 5 6 7 8 9 Enter ...

Page 81: ...74 C ASCII Table NULL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 ...

Page 82: ...75 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SPACE ...

Page 83: ...76 Comma Minus Period 0 Number Zero 1 Number One 2 3 4 5 6 7 8 9 Less Than Greater Than ...

Page 84: ...77 A B C D E F G H I Letter I J K L M N O Letter O P Q R S T U ...

Page 85: ...78 V W X Y Z _ Underscore a b c d e f g h i j k ...

Page 86: ...79 l m n o p q r s t u v w x y z Vertical Slash DEL ...

Page 87: ...80 D Function Key Table F1 F7 F2 F8 F3 F9 F4 F10 F5 F11 F6 F12 Insert Delete Home End Page Up Page Down Left Right ...

Page 88: ...BS Plastic Connector RJ 45C 10Pins Dimension 130 6 mm L x 112 2 mm W x 84 6 mm H Operational Light Source Visible Red light 632nm LED Sensor Linear CCD Sensor Processor Type ARM Cortex M3 32 bit Operating Freq 8 MHz Scan Speed Smart detection up to maximum 500 scans sec Depth of Field Up to 500mm 20mil 0 5mm PCS90 Code39 Print Contrast Ratio PCS45 5mil 0 127mm Minimum Resolution 4mil 0 1mm PCS90 C...

Page 89: ...r On 400mA Stand by 270mA Operation 290mA Sleep 36mA Cradle Voltage 5 VDC 2A Input AC 110 240V Cradle LED Indicator Good read Green Transmitted Success Blue Power Consumption Power On 95mA Stand by 55mA Operation 70mA Radio Characteristics Bluetooth Module Bluetooth V2 0 Standard Frequency Band 2 402GHz 2 480GHz Modulation Method GFSK for 1Mbps RF Output Power Class 1 under 20dBm Transmission Rang...

Page 90: ...ity 20 to 95 non condensing Ambient Light Immunity 10 000 LUX max Direct sun Light Ingress Protection Sealed with IP42 rating protection Scanner Drop Specification Functions normally after repeated 1 2m 4ft drops to concrete surface Sealing IP42 Regulatory of Compliance FCC CE F Scan Map Typical Reading Distance ...

Page 91: ...times Be Be Transmitted Green Blink 1 time Be Succeed Transmitted Fail Red Blink 2 times Be Be Configure Setup Green Light and Buzzer Simultaneously Bi Bi Bi BT Connecting Build Blue Blink 2 times per second N A BT Connecting Succeed Blue light 2 second Up Tone BT Connected Blue Blink per Second N A BT Disconnect Blue Light 2 Second Down Tone Charging Red Light Continue N A Full Charge Green Light...

Page 92: ...A Transmitted Succeed Green Blink 1 Time N A BT Connected Blue Blink Continue N A BT Disconnect Blue Blink 2 Times per Second N A H Test Symbologies Scan one or more of these bar codes to test symbologies you enabled 1D Symbology Codabar NW7 CODE 11 CODE 39 CODE 93 CODE 128 EAN 8 ...

Page 93: ...90128 0 12345 67890 5 0 123456 5 EAN 13 Interleave 2 of 5 ISBN ISSN GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 Databar Limited MSI Plessey Matrix 2 of 5 Industrial 2 of 5 UPC A UPC E Telepen China Postage ...

Page 94: ...87 QUICK CONFIGURATION Start Configuration Select your Settings End Configuration Save Parameters Set All Defaults Recall Stored Parameters Abort Configuration Version Information ...

Reviews: