Hardware
Rev 2 Jun.16
27
4118903
Figure 2-14: UART1 Configuration
UART2
The primary CF3 module’s UART2 signal connects via a MUX to one of the following sources, as
shown in
•
RS-232 DB9 serial connector (CN700)—Default configuration
•
IoT Connector 2 (CN1002)
The UART2 interface configuration can be modified as detailed in
.
Figure 2-15: UART2 Configuration
Main CF3
UART1
IoT Connector #0
(CN1000, slot IOT0)
UART
IoT Connector #1
(CN1001, slot IOT1)
UART
ATMega32U4
(U1500)
UART
Note: Green arrows show default
hardware configuration
Mux1
Mux2
Table 2-10: UART2 Interface Configuration Changes
Change type
Change effect
Method
Change duration
Software
Mux1—Use default or
alternate configuration.
API command
Modifies running
configuration until device
reboots or another change is
made.
Hardware
Mux1—Use default or
alternate configuration
Set resistor on Mux1:
•
Low—Default
•
High—Alternate
Selected configuration used
every time device boots up.
Mux1
RS-232 DB9
(CN700)
Transceiver
Main CF3
UART2
IoT Connector #2
(CN1002, slot IOT2)
UART
Note: Green arrows show default
hardware configuration