Page ... 15
V4 - June 2016
4.
MAINTENANCE
Perform all recommended maintenance procedures before using the log splitter.
a)
Check the entire machine for damaged, worn or broken
parts. Replace any defective parts before using the
machine.
Splitter Blade
(Fig 3)
a)
Inspect the wear strip (1) the blade base (2) main beam (3)
and bottom plate (4) for wear and damage.
b)
Check the edge of the blade (5) and sharpen if required.
Hydraulic Oil Filter
(Fig 4).
a)
The hydraulic filter is located in the top of the hydraulic tank.
b)
To service the filter undo the three bolts (1) on top plate, Remove
the top plate (2), remove the filter element and fit the new
element.
c)
Change the hydraulic filter element every 500 hours or every six
months.
d)
Examine the used filter element for any unusual contamination, if
any metal particles are found check the system for the cause or
contact the service agent. Disconnect the filter cartridge and
replace.
Engine
The engine maintenance is fully covered in the engine instruction handbook delivered with the unit.
However the following list of instructions are the minimum required for daily maintenance.
a)
Check the engine oil and fill if required, do not overfill.
b)
Check the fuel level and fill if required, do not overfill the tank.
c)
Check all hoses for leaks. Check joints, wires, cables and leads for damage and wear,
replace immediately if damage is found.
d)
Check the engine for loose parts, do not start the engine with insecure and loose parts.
Hydraulic System and Components
Daily check all hydraulic hoses for leaks, wear, cracking, kinks and chaffing. Replace any defective
hose immediately.