6. OPERATION & BASS MANAGEMENT  

The 2520P monitor are specially designed to be used in combination with M&K Sound subwoofers, both in 
setups with “external” bass management control units or without.

Using 2520P with the M&K Sound BMC-1 Bass management controller for 2 channel or multi-channel mix 
setup, will provide the most correct set up conditions for 2520P and subwoofer(s). The M&K Sound BMC-1 
Bass Management controller offers professional balanced connections for high pass and low pass filtering, 
with individual channel level calibration for 2.1 or 5.1 setups for direct connection to 2520P monitors and 
M&K Sound subwoofers.  

Wide / Narrow directivity selector 

Select “Wide Mode” when 2520P are to be used as a 
“free-standing” speakers in near to mid field positions. 

Optional select “Narrow Mode” to activate vertical directivity 
control for nearfield listening, if placing 2520P direct on mixing 
consoles or close to reflecting surfaces. 

Main Power on/off 

Turns the system on/off.
Status LED are present on front and back of speaker.  

Fuse holder

Fuse type T5AL      250Volt for 110 / 120 Volt    
Fuse type T3.15AL 250 volt for 220 / 240 Volt
Caution! Always disconnect power cord before changing fuse,
Replace fuse only with same type.

Main Power socket 

Use the included power chord for the main power connection.  

Voltage selector 115 / 230 Volt.   

Caution! 
Always disconnect power cord and check the fuse has correct 
value before changing the input voltage. 

  

I

J

K

L

M

2520P High pass filter shall be set to position “OUT” when used together with M&K Sound Bass 
management controller, and subwoofer crossover setting shall be “BY-PASSED” - as the Bass management 
control unit will handle correct filtering for signals send to monitors and subwoofers.  

When using the 2520P without a bass management control unit, the 2520P High pass filter shall be 
activated to “IN” position” to cut of low frequency bass content from the monitors.

Connecting the M&K Sound subwoofers using the 2520P “Pass Thru” outputs create good “bass logic” 
when either using 1 or 2 M&K Sound subwoofers, as M&K Sound subwoofers are featured with dedicated 
input sockets for mono sub signals and Left and Right input signals.
 
In case of using 1 sub, the Left & Right main signal outputs from a mixer or monitor controller shall be 
connected to the 2520P inputs for respective Left & Right speakers inputs, and by using the 2520P “Pass 
Thru” output socket – the main signals will be carried on to the subwoofers and summed internally in the 
subwoofer. The use of both Left & Right inputs on the subwoofer, will provide correct bass output by “one 
subwoofer” in a given system setup. 
  
In case of using two subs, the main Left & right signal outputs from a mixer or monitor controller will also 
by using the “Pass Thru” connectors on the 2520P – route each main channel signal from source to each 
subwoofer, which logically shall be connected to the subwoofers mono input socket. 
   
In setups without a dedicated Bass Management controller, the subwoofers internal crossover filter 
setting is the crucial feature to adjust for perfect match to the 2520P monitors. Typically, it will be 
subwoofer crossover setting in the range between 100-120, Hz that will make good summation between a 
pair of 2520P monitors and subwoofers.        

When using 2520P together with other types of “studio monitor controllers” or HiFi preamps featured 
with dedicated subwoofer output connections, then make sure to firmly check how these operates for sub 
bass content.  
Some units just have their left and right channels summed into a common “sub out” channel, while 
the main channels at the same time provide full frequency bandwidth to their respective left and right 
channel outputs.

In such setups the 2520P is recommended to operate with high pass filter activated (“IN” position) alike 
setups without   External Bass Management” - to make sure the Bass response of the 2520P will be 
properly filtered.   

If the studio monitor controller or HiFi preamp itself offers both high pass and low pass filtering, the 
2520P shall be set to operate with High pass filter “out”, as then the monitor controller or HiFi preamp 
will handle the crossover filtering between the subwoofer and 2520P monitor. 

Using the 2520P with modern surround sound amplifiers or processors, the Bass management control will 
be present by the surround sound “equipment”, and the 2520P shall also in such setups operate with High 
pass filter in “OUT” position. 

Modern surround amplifiers, processors and monitor controllers are according to their build in decoding 
processors for various surround sound formats and crossover filter options, not always made with same 
designs, and some products may offer more features than others. 
Normally the basic options for proper Bass management control will be present in such dedicated 
equipment, but always check the actual unit for their technical specifications, to make sure proper Bass 
management control is possible to make, when using the 2520P monitor and M&K subwoofers in such 
setups.  

Summary of Contents for MPS2520P

Page 1: ...3 M P S 2 5 2 0 P P R O F E S S I O N A L M O N I T O R OPERATION MANUAL MPS2520P PROFESSIONAL MONITOR Ver 1 0 MAY 2018 M K Sound Denmark www mksound com ...

Page 2: ... personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normal ly or has been dropped 15 The equipment shall be used at maximum 35 de gree C ambient temperature 16 Do not open the equipment to redu...

Page 3: ...gle équilatéral vous avertit de l existence d instructions importantes de fonctionnement et d entretien intervention dans la documentation accompagnant l appareil ATTENTION RISQUE DE CHOC ÉLECTRIQUE PAS OUVRIR The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that ma...

Page 4: ...ntrol 7Switch position REF are calibrated for 90dB of acoustic output at one meter with drive signal 200mV Use switch position REF when connecting 2520P to surround receivers 2 channel preamps or surround processors Use switch position 4dBu for connection to professional mixing consoles or monitor controllers Switch position Variable Gain offers variable gain from 6dB to 6dB relative to the refere...

Page 5: ...akers inputs and by using the 2520P Pass Thru output socket the main signals will be carried on to the subwoofers and summed internally in the subwoofer The use of both Left Right inputs on the subwoofer will provide correct bass output by one subwoofer in a given system setup In case of using two subs the main Left right signal outputs from a mixer or monitor controller will also by using the Pas...

Page 6: ...eak Bass midrange 2 x 5 25 Glass fibre High frequency drivers 3 x 1 1 soft fabric dome Frequency response 80 12KHz 1dB 12 20KHz 2dB Total Harmonic distortion 0 002 into 4 ohms LF Channel 0 03 into 4 ohms HF channel Signal to noise ratio 100dB AC power consumption Standby Average Max 17W 45W 360W AC line voltage 115VAC 60Hz 5A 230VAC 60Hz 3 15A Input impedance unbalanced 11Kohm balanced 22Kohm Inpu...

Reviews: