background image

 

 

 

Temperature controller 701  |  1.01.00 

www.mc-techgroup.com

 

 
 
 
 
 
 
Dear Customer, 

 
Thank you for buying our product. In this manual you will find all necessary information about this M&C product. 
The information in the manual is fast and easy to find, so you can start using your M&C product right after you have 
read the manual. 

If you have any question regarding the product or the application, please don’t hesitate to contact M&C or your 
M&C authorized distributor. You will find all the addresses in the appendix of this instruction manual. 

For additional information about our products, please go to M&C’s website 

www.mc-techgroup.com

. There you 

can find the data sheets and manuals of our products in German and English. 
 

 

 

This Operating Manual does not claim completeness and may be subject to 
technical modifications.  
© 11/2022 

M&C 

Tech

Group 

Germany GmbH.  

Reproduction of this document or its content is not allowed without permission
from 

M&C

 
 
Version: 1.01.00

 

Summary of Contents for 701

Page 1: ...Electronic Temperature Controller 701 Effective from September 2020 Serial No 2009143 Instruction Manual Version 1 01 00...

Page 2: ...plication please don t hesitate to contact M C or your M C authorized distributor You will find all the addresses in the appendix of this instruction manual For additional information about our produc...

Page 3: ...or K 12 14 Initial starting 12 14 1 Overview 13 14 2 Functional test 14 15 Error messages 15 16 Measured value recording 15 17 Decommissioning 15 18 Maintenance and repair 16 19 Appendix 16 List of Il...

Page 4: ...tructions and warnings closely Read this manual carefully before commissioning and operating the device If you have any questions regarding the product or the application please don t hesitate to cont...

Page 5: ...ages This also applies to any external control circuits that are connected The device is only to be used within the permitted range of temperatures Check that the location is weather protected It shou...

Page 6: ...illed Caution This means that minor physical injuries may occur in case the respective safety measures are not fulfilled Caution Without the warning triangle means that a material damage may occur in...

Page 7: ...step regulator Temperature sensor input PT100 DIN 2 conductors with identification of sensor short circuit break protection Ambient temperature 0 to 55 C 32 to 131 F in case of close to close mounting...

Page 8: ...value and the target value are displayed on a dot matrix LCD The LCD display is black and white with backlight and 64 x 80 pixel resolution The control function is indicated by a K1 in the upper left...

Page 9: ...during transportation and if required inform your shipping insurance immediately of the damage found Note The controller should be stored in a weather protected and frost free area 10 1 PRODUCT LABEL...

Page 10: ...ndication on the type plate Warning When setting high power electrical units with nominal voltages of up to 1000 V attention must be paid to the requirements of VDE 0100 together with the associated s...

Page 11: ...output K1 zero current state 4 Optionally a multipole coupling socket can be mounted externally that will be wired with the temperature controller according to the pin connection plan see Figure 6 Th...

Page 12: ...to 2192 F Fe CuNi K DIN EN 60584 1 2014 270 bis 1300 C 454 to 2372 F 6 Select your thermocouple type and confirm your selection by pressing the menu button 14 INITIAL STARTING The thermostat function...

Page 13: ...www mc techgroup com Temperature controller 701 1 01 00 13 14 1 OVERVIEW Figure 8 Overview of settings and functions...

Page 14: ...hether the determined operating temperature is reached The first function test has to be effected as follows 1 Switch on the power supply 2 After the set point temperature is being reached the control...

Page 15: ...ck to M C TechGroup 16 MEASURED VALUE RECORDING Display Cause remedy or instruction for action Under range check sensor configuration check measuring chain Over range check sensor configuration check...

Page 16: ...iod of time In case the controller is defective please send the device to M C TechGroup for repair Note The controller is equipped with a sensor break protection that in case of need cuts off the unit...