Operation
MAN marine diesel engines D2868 LE4.. / D2862 LE4..
69
Carefully read through the Operating Instructions before starting any work!
This particularly applies to the General Safety Instructions section
and the safety instructions in the various chapters.
7.5.2
Display systems and instruments
Colour display MMDS-CLC 6.5
MAN can supply the MMDSCLC 6.5 colour display as an option.
This device registers the engine and gearbox sensor data.
Several graphic pages
1
depict the recorded measured values in the form of digital displays and circular
gauges. For further graphic pages, see page 72.
If a value reaches a critical level, a warning message or an alarm is tripped and shown on the display, de
pending on importance
2
. If the value exceeds certain plausible limits, a sensor fault is displayed. An in
tegrated buzzer emits a warning sound each time a new alarm message is issued. This sound can be
stopped at the push of a button.
Navigation through the various monitoring and alarm pages is possible using the buttons directly on the
display
3
. The language, desired system of units, date, time and display contrast can be set by means of
screen menu.